Design and Evaluation of a Continuous Flow , Integrated Nebulizer - Hydride Generator for Flame Atomic Absorption Spectrometry

نویسندگان

  • Nereida Carrión
  • Jorge Colmenares
  • Juan Romero
  • Gladys Alvarado
  • Manuel Ríos
  • Freddy Angulo
چکیده

An evaluation of the performance of a continuous flow hydride generator-nebulizer for flame atomic absorption spectrometry was carried out. Optimization of nebulizer gas flow rate, sample acid concentration, sample and tetrahydroborate uptake rates and reductant concentration, on the As and Se absorbance signals was carried out. A hydrogen-argon flame was used. An improvement of the analytical sensitivity relative to the conventional bead nebulizer used in flame AA was obtained (2 (As) and 4.8 (Se) μg L). Detection limits (3 b) of 1 (As) and 1.3 (Se) μg L were obtained. Accuracy of the method was checked by analyzing an oyster tissue reference material

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Flotation/magnetic stirring-assisted liquid-liquid microextraction combined with flame atomic absorption spectrometry for the preconcentration and determination of cadmium (II) after optimization using experimental design

Arapid, highly sensitive and efficient flotation/magnetic stirring-assisted liquid-liquid microextraction combined with flame atomic absorption spectrometry has been proposed for the preconcentration and quantitative analysis of trace amounts of cadmium (II) in the presence of sodium diethyldithiocarbamateas complexingagent. Parameters including sample pH, concentration of the complexingagent, ...

متن کامل

Application of Sulfur Nanoparticles as a Solid Phase Extraction Sorbent for the Preconcentration of Lead(II) and Palladium(II) in Environmental Samples Prior to Flame Atomic Absorption Spectrometry Determination

The application of sulfur nanoparticles as an efficient adsorbent for the solid-phase extraction and determination of the trace amounts of Pb and Pd ions was investigated in environmental samples using flame atomic absorption spectrometry. Effects of various parameters such as pH, flow rate of sample and eluent, type and concentration of eluent, sample volume, amount of adsorbent and interferin...

متن کامل

On-line hyphenation of hydride generation with in situ trapping flame atomic absorption spectrometry for arsenic and selenium determination.

The analytical performances of coupled hydride generation, integrated atom trap (HG-IAT) atomizer flame atomic absorption spectrometry (FAAS) systems were evaluated for determination of As and Se in biological and environmental reference materials. Arsenic and Se hydrides are atomized in air-acetylene flame-heated IAT. A new design of HG-IAT-FAAS hyphenated technique that would exceed the opera...

متن کامل

Continuous in vivo monitoring of blood diffusible calcium using on-line microdialysis sampling coupled with flame atomic absorption spectrometry.

A direct, rapid and continuous in vivo monitoring of diffusible calcium in the blood of living rabbits has been developed using microdialysis sampling coupled on-line with flame atomic absorption spectrometry. Microdialysates perfused through implanted microdialysis probes were collected with a sample loop on an injection valve and directly introduced into the flame atomizer by a carrier soluti...

متن کامل

Dispersive liquid–liquid microextraction based on solidification of floating organic drop combined with flame atomic absorption spectrometry for determination trace amount of cobalt in water samples

An efficient, rapid, simple, and highly selective dispersive liquid–liquid microextraction basedon solidification of floating organic drop (DLLME-SFOD), combined with flame atomicabsorption spectrometry was developed for preconcentration and determination of trace amountsof cobalt in water samples. In this method, an appropriate mixture of acetone and1-undecanol was injected rapidly into the aq...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008