Electrocardiographic patch devices and contemporary wireless cardiac monitoring
نویسندگان
چکیده
Cardiac electrophysiologic derangements often coexist with disorders of the circulatory system. Capturing and diagnosing arrhythmias and conduction system disease may lead to a change in diagnosis, clinical management and patient outcomes. Standard 12-lead electrocardiogram (ECG), Holter monitors and event recorders have served as useful diagnostic tools over the last few decades. However, their shortcomings are only recently being addressed by emerging technologies. With advances in device miniaturization and wireless technologies, and changing consumer expectations, wearable "on-body" ECG patch devices have evolved to meet contemporary needs. These devices are unobtrusive and easy to use, leading to increased device wear time and diagnostic yield. While becoming the standard for detecting arrhythmias and conduction system disorders in the outpatient setting where continuous ECG monitoring in the short to medium term (days to weeks) is indicated, these cardiac devices and related digital mobile health technologies are reshaping the clinician-patient interface with important implications for future healthcare delivery.
منابع مشابه
A Wireless Electronic Esophageal Stethoscope for Continuous Monitoring of Cardiovascular and Respiratory Systems during Anaesthesia
Background: The basic requirements for monitoring anesthetized patients during surgery are assessing cardiac and respiratory function. Esophageal stethoscopes have been developed for this purpose, but these devices may not provide clear heart and lung sound due to existence of various noises in operating rooms. In addition, the stethoscope is not applicable for continues monitoring, and it is u...
متن کاملECG patch monitors for assessment of cardiac rhythm abnormalities.
The primary goal of long-term monitoring is the improvement of diagnostic yield. Despite the clear utility of Holter monitoring in clinical cardiology, issues of relatively low diagnostic yield, cost and inconvenience have motivated the development of ultra-portable devices referred to as ECG patch monitors. Although the "gold standard" for assessing cardiac rhythm abnormalities remains a 12-le...
متن کاملUtility of Duranta, a wireless patch-type electrocardiographic monitoring system developed in Japan, in detecting covert atrial fibrillation in patients with cryptogenic stroke
RATIONALE Subcutaneous implantable electrocardiographs are highly effective in detecting covert atrial fibrillation (AF) in cryptogenic stroke. However, these invasive devices are not indicated for all cryptogenic stroke patients, and noninvasive improvements over conventional Holter-type ambulatory electrocardiography are needed. We evaluated the clinical application and effectiveness of Duran...
متن کاملElectrocardiographic manifestation of digoxin toxicity in a Pomeranian dog
This case report describes several electrocardiographic findings in an 8-years old female Pomeranian dog that was referred with a history of digoxin overdose. Electrocardiographic abnormalities detected in this case could be classified as primary electrocardiographic disturbances, reflecting cardiac chamber enlargement and secondary ECG changes, attributed to digoxin toxicity. ECG manifestatio...
متن کاملErosive Pressure Dermatitis Associated with Cardiac Pacemaker
Erosive dermatitis is a skin reaction associated with implantable cardiac devices (ie, pacemakers and cardioverter defibrillators). We report a 65-year-old man with a history of several cerebrovascular attacks who developed an erythematous crusted erosive patch over the pacemaker site after implantation of two subsequent pacemakers. We suggest that physical irritation may be a trigger factor fo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 6 شماره
صفحات -
تاریخ انتشار 2015