Parameters of unimplanted and explanted surfaces of Weller endoprosthesis stems.

نویسندگان

  • Janusz Cwanek
  • Andrzej Antoni Czajkowski
چکیده

40 samples of stem surfaces of the Weller endoprosthesis of hip joint removed because of aseptic loosening were tested. The patients between the ages of 61 and 87 were examined and the exploitation time of endoprosthesis ranged from 1 to 20 years. The material analysed was as follows: I group - exploitation 1-3 years (5 surfaces), II group - exploitation 5-8 years (11 surfaces), III group - exploitation 10-14 years (14 surfaces), and IV group - exploitation 16-20 years (10 surfaces). Additionally group 0 covered 4 unexploited endoprostheses. We analysed the 2-4 mm2 surfaces of the Weller endoprosthesis stems, with the scan velocity of 500 mum/s. A decrease in stem amplitude parameters means some increase in stem microdisplacements in relation to cement. During the first three years, the decrease in the roughness of endoprosthesis surface was larger compared with that in further exploitation period. In the case of unexploited surfaces of stems, the values of fractal dimension are lower (2.34). During exploitation time the Sfd parameter decreases negligibly (2.28-2.24).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Impact of overweight on the durability of Weller prostheses.

Background. The goal of our research was to assess overweight as a risk factor for reduced survivability of Weller-type artificial cement hip joints. Material and methods. We studied 71 patients (26 men, 45 women) diagnosed with aseptic loosening of Weller endoprostheses. The age of the patients ranged from 62 to 87 years of life (mean 74.3 +/- 6.0), the exploitation time of the artificial hip-...

متن کامل

Hardness and friction of N: and Al+ implanted B4C

Surfaces of boron carbide (B4C) were implanted with 200 keV N: or 100 keV AI + ions to a dose of 8 x 10” cm‘. Ultralow load indentation via the Nanoindenter was used to determine the changes in surface hardness and elastic modulus following implantation. A pin-on-disk testing device in ultrahigh vacuum was used for measuring changes in friction and wear of the implanted disks. Results of hardne...

متن کامل

Kinetics and Equilibrium Studies of the Removal of Blue Basic 41 and Methylene Blue from Aqueous Solution Using Rice Stems

Synthetic dyes are among the most common contaminants of the environment. Therefore, the aim of this study was investigation the removal of Basic Blue 41 (BB41) and Methylene Blue (MB) from industrial effluents by useing raw and modified rice stems. In this study raw and modified rice stems treated chemically with Citric Acid (CA) and were used to explore the potentiality of rice stems for ...

متن کامل

Calcification and Oxidative Modifications Are Associated With Progressive Bioprosthetic Heart Valve Dysfunction

BACKGROUND Bioprosthetic heart valves (BHVs), fabricated from glutaraldehyde-pretreated bovine pericardium or porcine aortic valves, are widely used for the surgical or interventional treatment of heart valve disease. Reoperation becomes increasingly necessary over time because of BHV dysfunction. METHODS AND RESULTS Forty-seven explanted BHV aortic valve replacements were retrieved at reoper...

متن کامل

Practical considerations for volumetric wear analysis of explanted hip arthroplasties

OBJECTIVES Wear debris released from bearing surfaces has been shown to provoke negative immune responses in the recipient. Excessive wear has been linked to early failure of prostheses. Analysis using coordinate measuring machines (CMMs) can provide estimates of total volumetric material loss of explanted prostheses and can help to understand device failure. The accuracy of volumetric testing ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Acta of bioengineering and biomechanics

دوره 11 2  شماره 

صفحات  -

تاریخ انتشار 2009