Time-related changes in the cross-sectional area of the tibial tunnel after compaction of an autograft bone dowel alongside a hamstring graft.

نویسندگان

  • Akio Matsumoto
  • Stephen M Howell
  • David Liu-Barba
چکیده

PURPOSE Extensive tunnel expansion in hamstring anterior cruciate ligament (ACL) reconstruction can complicate revision surgery. The purpose of this study was to examine our hypothesis that compaction of a bone dowel into the tibial tunnel reduces the cross-sectional area of the tunnel on the day of surgery and limits tunnel expansion to that of the cross-sectional area of the reamer at 4 months and 1 to 2 years. METHODS A bone dowel averaging 23 mm in length and 7 mm in diameter was harvested from the tibial tunnel in 10 patients undergoing hamstring ACL reconstruction. The tibial tunnel was dilated, and the bone dowel was compacted anterior to the tendon graft. The cross-sectional area of the tibial tunnel was calculated on the day of surgery and at 4 months and 1 to 2 years postoperatively from computed tomography scans. RESULTS On the day of surgery, the cross-sectional area of the tibial tunnel was 34% smaller than the 50-mm2 cross-sectional area of the 8-mm reamer used to drill the tunnel (P < .001). At 1 to 2 years, the cross-sectional area of the tibial tunnel was smaller than that of the reamer in 6 subjects, was slightly larger (53 to 56 mm2) in 3 subjects, and was substantially larger (80 mm2) in 1 subject. CONCLUSIONS A surgeon who compacts an autogenous bone dowel into the tibial tunnel alongside a hamstring graft can expect little to no tunnel expansion in 90% of patients at 1 to 2 years. To our knowledge, the limitation of tunnel expansion to that of the cross-sectional area of the reamer has not been shown with other tibial fixation techniques. LEVEL OF EVIDENCE Level IV, therapeutic case series.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Compaction of a bone dowel in the tibial tunnel improves the fixation stiffness of a soft tissue anterior cruciate ligament graft: an in vitro study in calf tibia.

BACKGROUND Despite increasing attention on fixation of a soft tissue anterior cruciate ligament graft in the tibia, there have been no studies on the use of a bone dowel as a joint line fixation device for promoting fixation properties, especially stiffness at the time of implantation. PURPOSE To determine whether compacting a bone dowel into the tibial tunnel improves fixation stiffness, yie...

متن کامل

Injury to the Infrapatellar Branch of the Saphenous Nerve during ACL Reconstruction with Hamstring Tendon Autograft: A Comparison between Oblique and Vertical Incisions

Background: Injury to the infrapatellar branch of the saphenous nerve (IPBSN) is common after arthroscopic ACLreconstruction with hamstring tendon autograft, as reported in up to 88% of the cases. Due to close relationshipbetween the IPBSN with pes anserine tendons insertion skin incision may sever IPBSN while harvesting gracillis andsemitendinous tendons. As the IPBSN course at the anterior of...

متن کامل

Bone Tunnel Impaction Reduced the Tibial Tunnel Enlargement

The purpose of this study was to investigate whether the bone tunnel impaction technique performed by dilators could dwindle the tibial tunnel enlargement after anterior cruciate ligament (ACL) reconstruction with hamstring tendon using both extracortical suspensory fixation devices at femoral and tibial site. Thirty-one consecutive patients undergoing primary ACL reconstruction with the hamstr...

متن کامل

The effect of early motion on tibial tunnel widening after anterior cruciate ligament replacement using hamstring tendon grafts.

PURPOSE The purpose of this study was to evaluate the hypothesis that early motion increases tibial tunnel enlargement in patients who underwent anterior cruciate ligament (ACL) replacement with hamstring autograft. TYPE OF STUDY Cohort analytic study. METHODS All patients in this study had received a doubled semitendinous and gracilis graft. Grafts were secured in place with an implant-fre...

متن کامل

One-Year Serial Follow-up Magnetic Resonance Imaging Study of RigidFix for Femoral Fixation in Anterior Cruciate Ligament Reconstruction

Purpose To assess graft slippage at the site of femoral fixation by follow-up magnetic resonance imaging (MRI) after anterior cruciate ligament (ACL) reconstruction with a four-strand autogenous hamstring tendon using RigidFix (DePuy Mitek). Materials and Methods Twenty-one subjects diagnosed with ACL rupture underwent ACL reconstruction using hamstring autograft with the transtibial techniqu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association

دوره 22 8  شماره 

صفحات  -

تاریخ انتشار 2006