Distal Femur Morphology of Iranian Population and Correlation With Current Prostheses.
نویسندگان
چکیده
BACKGROUND Maintaining proper size and rotation of components of total knee arthroplasty is mandatory for optimal longevity. Ethnical differences may affect the fitness of prostheses that were manufactured mainly based on Caucasian dimensions. OBJECTIVES To evaluate the distal femur morphology of the Iranian population at the level of standard cuts simulated via computed tomography. PATIENTS AND METHODS During 2013, 150 consecutive patients (96 males and 54 females) from the outpatient Department of Orthopedic Surgery of Rasoul Akram Hospital with knee CT scans were studied. We entered cases with apparent normal extremity alignment and bone maturity. Exclusion criteria were history of fracture or conditions affecting knee profile. Standard cuts were simulated on the CT scan using the Marco Pacs program. For each bone, anteroposterior (AP), mediolateral (ML), and aspect ratio (ML/AP) were measured. Values were compared with the sizing of four currently available prostheses. RESULTS The mean age of the patients was 43 years (range: 17 to 80). All isolated parameters were higher in men significantly (P < 0.001). However, the aspect ratio did not show any significant difference (1.51 ± 0.11 vs 1.46 ± 0.1), suggestive of a similar configuration of distal femur profiles between genders. Ultimately, close correlations were observed among simulated cuts and size-matched femoral components of the prostheses. For females, however, components were mostly overhang mediolaterally except for one gender-specific subset. Decrement in the aspect ratio for larger knees was another mismatch with current prostheses that preserve an almost constant ratio throughout all sizes. CONCLUSIONS Our findings may be applied by manufacturers to design prostheses more compatible with Asian populations. Alterations to the shape of components should be considered to provide optimal coverage.
منابع مشابه
Anthropometric Measurements of Distal Femur to Design the Femoral Component of Total Knee Arthroplasty for the Iranian Population
Background: Acquiring knowledge about anatomic and geometric quantities of bones is among the most vitalparameters in orthopedic surgery that has a significant effect on the treatment of various disorders and subsequentoutcomes. The aim of this study was to obtain anthropometric information for distal femur in order to compare withsimilar dimensions of prosthesis used in total...
متن کاملEvaluation of Distal Femoral Rotational Alignment with Spiral CT Scan before Total Knee Arthroplasty (A Study in Iranian Population)
Background: Evaluating the landmarks for rotation of the distal femur is a challenge for orthopedic surgeons. Although the posterior femoral condyle axis is a good landmark for surgeons, the surgical transepicondylar axis may be a better option with the help of preoperative CT scanning. The purpose of this study was to ascertain relationships among the axes’ guiding distal femur rotational ...
متن کاملMorphology of proximal tibia in Iranian population and its corre-lation with available prostheses
Background: Total knee arthroplasty is a complex procedure aiming to relieve pain and improve function. It is critical to select prosthesis that best cover the bone surfaces. Ethnicity may affect fitness of the components mainly designed for Caucasian populations. This study aimed to evaluate morphometric features of proximal tibia in Iranian population. Methods : During 2013, 150 consecuti...
متن کاملAnthropometric measurements of knee joints in Thai population: correlation to the sizing of current knee prostheses.
Anthropometric data on the distal femoral condyle and the proximal tibia of 200 knees in 200 Thai subjects were measured using magnetic resonance imaging (MRI). The data including the resected femoral anterior-posterior (AP) length, the resected femoral medial-lateral (ML) width, the resected tibial AP length and the resected tibial ML width were measured. A characterization of the aspect ratio...
متن کاملEconomic Analysis of Bisphosphonate Use after Distal Radius Fracture for Prevention of Hip Fracture
Background: Osteoporosis is a common condition among the elderly population, and is associated with an increased risk of fracture. One of the most common fragility fractures involve the distal radius, and are associated with risk of subsequent fragility fracture. Early treatment with bisphosphonates has been suggested to decrease the population hip fracture burden. However, there have been no p...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Iranian Red Crescent medical journal
دوره 18 2 شماره
صفحات -
تاریخ انتشار 2016