Convective cooling effect on cooled-tip catheter compared to large-tip catheter radiofrequency ablation.

نویسندگان

  • Thomas A Pilcher
  • Anna L Sanford
  • J Philip Saul
  • Dieter Haemmerich
چکیده

BACKGROUND Both actively cooled-tip and large-tip catheters are currently available clinically to create large endomyocardial lesions during application of radiofrequency (RF) energy. The purpose of this study was to compare the effect of convective cooling at physiologic flow rates on RF lesion size using both actively cooled and large-tip catheters. METHODS Porcine hearts were sectioned into 72 pieces and placed in a temperature-controlled saline bath (37 degrees C) with varying directed flow rates (0, 1, 2, and 3 L/min). Cooled-tip RF ablation (4 mm tip) was performed for 1 minute on 36 tissue sections with power manually titrated to keep tip temperature below 40 degrees C. Large-tip catheter ablation (10 mm tip) was performed at 65 degrees C target temperature for 1 minute on 36 tissue sections. For each catheter, flow rates were randomized between applications. The tissue pieces were sectioned and measured to determine lesion depth, width, and volume. RESULTS Lesion dimensions were independent of the flow rate for the cooled-tip catheter (mean volumes: 382.0 +/- 121.6, 419.9 +/- 133.4, 375.9 +/- 169.1, and 346.7 +/- 173.4 mm(3) for 0, 1, 2, and 3 L/min flow rate, respectively, P = 0.78). For the large-tip catheter, lesion size varied significantly with flow, such that higher flow rates produced larger lesions (mean volumes: 120.7 +/- 50.7, 256.5 +/- 97.9, 393.4 +/- 149.9, and 548.9 +/- 157.0 mm(3) for 0, 1, 2, and 3 L/min flow rate respectively, P < 0.001) CONCLUSION During RF ablation, blood flow rate significantly affects lesion size for large-tip but not cooled-tip catheters. At low flow rates (0-1 L/min) cooled-tip catheters create larger lesions, while at high flow rates (3 L/min) large-tip catheters create larger lesions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Lesion dimensions during temperature-controlled radiofrequency catheter ablation of left ventricular porcine myocardium: impact of ablation site, electrode size, and convective cooling.

BACKGROUND It is important to increase lesion size to improve the success rate for radiofrequency ablation of ischemic ventricular tachycardia. This study of radiofrequency ablation, with adjustment of power to approach a preset target temperature, ie, temperature-controlled ablation, explores the effect of catheter-tip length, ablation site, and convective cooling on lesion dimensions. METHO...

متن کامل

Catheter ablation of ventricular epicardial tissue: a comparison of standard and cooled-tip radiofrequency energy.

BACKGROUND Transthoracic epicardial catheter ablation is an emerging catheter ablation strategy being used clinically at increasing frequency. However, the efficacy of standard RF ablation on the epicardial surface of the heart is hindered by (1) the lack of convective cooling of the ablation electrode and (2) the varying presence of epicardial adipose tissue interposed between the ablation ele...

متن کامل

Catheter Ablation of Ventricular Epicardial Tissue

Background—Transthoracic epicardial catheter ablation is an emerging catheter ablation strategy being used clinically at increasing frequency. However, the efficacy of standard RF ablation on the epicardial surface of the heart is hindered by (1) the lack of convective cooling of the ablation electrode and (2) the varying presence of epicardial adipose tissue interposed between the ablation ele...

متن کامل

Effect of isthmus anatomy and ablation catheter on radiofrequency catheter ablation of the cavotricuspid isthmus.

BACKGROUND Cavotricuspid isthmus (CTI) characteristics are rarely documented when comparing catheters in radiofrequency ablation (RFA) of atrial flutter (AFL). Our objectives were (1) to evaluate the impact of CTI morphology and length on ablation procedures and (2) to compare the efficacy of an 8-mm-tip catheter with an irrigated cooled-tip RFA in the subgroup presumed to be more difficult to ...

متن کامل

Prospective randomised comparison of irrigated-tip and large-tip catheter ablation of cavotricuspid isthmus-dependent atrial flutter.

BACKGROUND Radiofrequency (RF) ablation of cavotricuspid isthmus (CTI) dependent flutter can be performed using different types of ablation catheters. It has been proposed that irrigated and large-tip catheters are capable of creating larger lesions, resulting in greater efficacy. This prospective, randomised clinical study compared the efficacy of irrigated and large-tip catheters of different...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Pacing and clinical electrophysiology : PACE

دوره 29 12  شماره 

صفحات  -

تاریخ انتشار 2006