Stator Inter-turn Fault Detection in Inverter Fed Induction Motor Drives
نویسندگان
چکیده
Received Mei 9, 2017 Revised Jun 20, 2017 Accepted Jul 27, 2017 The Squirrel Cage Induction motor(SCIM) with advanced power electronic inverters presents the greater advantages on cost and energy efficiency as compared with other industrial solutions for varying speed applications. In recent, the inverter fed induction motors are being popular in the industries. These inverter fed-motors are recently gathering great recognition for multimegawatt industrial drive applications. In this present paper, a dynamic simulation model of PWM inverter fed SCIM with direct torque control jointly has been presented and analyzed in the recent MATLAB/Simulink environment. From the proposed simulation model, the transient behavior of SCIM has been analysed for healthy as well as for stator inter-turn fault condition. The dynamic simulation of induction motor is one of the key steps in the validation of design process of the electric motor and drive system. It is extremely needed for eliminating probable faults beforehand due to inadvertent design mistakes and changes during operation. The simulated model gives encouraging results with reduced harmonics [1]. By using the model, the successful detection of stator inter-turn fault of the SCIM is carried out in the transient condition. Therefore, early stator fault detection is possible and may avoid the motor to reach in the catastrophic conditions. Therefore, may save millions of dollars for industries. Keyword:
منابع مشابه
Stator Turn-to-Turn Fault Detection of Induction Motor by Non-Invasive Method Using Generalized Regression Neural Network
Condition monitoring and protection methods based on the analysis of the machine's current are widely used according to non-invasive characteristics of current transformers. It should be noted that, these sensors are installed by default in the machine control center. On the other hand, condition monitoring based on mathematical methods has been proposed in literature. However, they are model b...
متن کاملSensorless Model Predictive Force Control with a Novel Weight Coefficients for 3-Phase 4-Switch Inverter Fed Linear Induction Motor Drives
The sensorless model predictive force control (SMPFC) is a strong method for controlling the drives of three-phase 4(6)-switch inverter linear induction motors. This kind of inverter can be employed for fault tolerant control in order to solve the problem of open/short circuit in 6-switch inverters (B6). This paper proposed a method for the SMPFC of a linear induction motor (LIM) with a 4-switc...
متن کاملStator and Rotor Faults Monitoring of the Inverter-Fed Induction Motor Drive using State Estimators
The paper deals with the application of the Extended Kalman Filter and the Extended Luenberger Observer algorithms for the stator and rotor fault detection of the induction motor fed by PWM inverter. The induction motor conditions are analyzed using estimated rotor and stator-winding resistance. Mathematical models of the extended state estimators are presented, in which the stator and rotor re...
متن کاملBroken rotor bar fault detection in inverter-fed squirrel cage induction motors using stator current analysis and fuzzy logic
This paper presents the implementation of broken rotor bar fault detection in an inverter-fed induction motor using motor current signal analysis (MCSA) and prognosis with fuzzy logic. Recently, inverter-fed induction motors have become very popular because of their adjustable speed drive. They have been used in many vital control applications such as rolling mills, variable speed compressors, ...
متن کاملStator Fault Detection in Induction Machines by Parameter Estimation Using Adaptive Kalman Filter
This paper presents a parametric low differential order model, suitable for mathematically analysis for Induction Machines with faulty stator. An adaptive Kalman filter is proposed for recursively estimating the states and parameters of continuous–time model with discrete measurements for fault detection ends. Typical motor faults as interturn short circuit and increased winding resistance ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2017