Fiberoptic monitoring of central venous oxygen saturation (PediaSat) in small children undergoing cardiac surgery: continuous is not continuous
نویسندگان
چکیده
BACKGROUND Monitoring of superior vena cava saturation (ScvO 2) has become routine in the management of pediatric patients undergoing cardiac surgery. The objective of our study was to evaluate the correlation between continuous ScvO 2 by the application of a fiber-optic oximetry catheter (PediaSat) and intermittent ScvO 2 by using standard blood gas measurements. These results were compared to those obtained by cerebral near infrared spectroscopy (cNIRS). SETTING Tertiary pediatric cardiac intensive care unit (PCICU). METHODS AND MAIN RESULTS A retrospective study was conducted in consecutive patients who were monitored with a 4.5 or 5.5 F PediaSat catheter into the right internal jugular vein. An in vivo calibration was performed once the patient was transferred to the PCICU and re-calibration took place every 24 hours thereafter. Each patient had a NIRS placed on the forehead. Saturations were collected every 4 hours until extubation. Ten patients with a median age of 2.2 (0.13-8.5) years and a weight of 12.4 (3.9-24) kg were enrolled. Median sampling time was 32 (19-44) hours: 64 pairs of PediaSat and ScVO2 saturations showed a poor correlation (r=0.62, 95% CI 44-75; p<0.0001) and an average difference of -0.38 with a standard deviation of 13 and 95% limits of agreement from -26 to 25. Thirty-six pairs of cNIRS and ScVO2 saturations showed a fair correlation (r=0.79, 95% CI 0.60-0.89; p<0.0001) an average difference of -1.3 with a standard deviation of 7 and 95% limits of agreement from -15 to 12. Analysis of median percentage differences between PediaSat and ScvO2 saturation over time revealed that, although not statistically significant, the change in percentage saturation differences was clinically relevant after the 8th hour from calibration (from -100 to +100%). CONCLUSION PediaSat catheters showed unreliable performance in our cohort. It should be further investigated whether repeating calibrations every 8 hours may improve the accuracy of this system. CNIRS may provide similar results with a lower invasiveness.
منابع مشابه
Fiberoptic monitoring of central venous oxygen saturation (PediaSat) in small children undergoing cardiac surgery: continuous is not continuous [version 3; referees: 2 approved]
Monitoring of superior vena cava saturation (ScvO ) has Background: become routine in the management of pediatric patients undergoing cardiac surgery. The objective of our study was to evaluate the correlation between continuous ScvO by the application of a fiber-optic oximetry catheter (PediaSat) and intermittent ScvO by using standard blood gas measurements. These results were compared to tho...
متن کاملUsefulness of central venous oxygen saturation monitoring during bidirectional Glenn shunt.
A PediaSat™ oximetry catheter (PediaSat: Edwards Lifesciences Co., Ltd., Irvine, CA, U. S. A.), which facilitates continuous measurement of central venous oxygen saturation (ScvO2), may be useful for surgery for pediatric congenital heart disease. We used PediaSat during a bidirectional Glenn shunt. The patient was a 13-month-old boy. Under a diagnosis of left single ventricle (pulmonary atresi...
متن کاملIn-vitro evaluation of the PediaSat continuous central venous oxygenation monitoring system.
BACKGROUND AND OBJECTIVE In-vitro performance of the PediaSat system for continuous monitoring of central venous oxygen saturation by spectrophotometry has been evaluated. METHODS PediaSat continuous fibre-optic oximetry catheters were inserted in a black testing chamber, connected with an extracorporeal circuit and filled with human whole blood. Oxygen inflow into the cardiopulmonary bypass ...
متن کاملContinuous Measurement of Central Venous Oxygen Saturation in Critically Ill Patients
gy allows critical care practitioners to continuously monitor and evaluate tissue oxygenation at the bedside by using a fiberoptic pulmonary artery catheter that measures mixed venous oxygen saturation (S–vO2). Placement of a pulmonary artery catheter to measure S–vO2 may not always be feasible early in resuscitation or outside the intensive care unit (ICU). A new technology that uses a modifie...
متن کاملContinuous monitoring of mixed venous oxygen saturation during aortic surgery.
The correlation between mixed venous oxygen saturation (SvO2) and hemodynamic measurements was studied in 13 patients undergoing descending thoracic aortic aneurysm resection (DTAAR). A significant correlation (p less than 0.05) was found between cardiac index (CI) and SvO2 after the induction of anesthesia and at the end of surgery. However, no significant correlation could be found between Sv...