A new method for recording a three-lead electrocardiogram using a two-channel Holter system.

نویسندگان

  • T Tanabe
  • Y Goto
چکیده

A technique for recording a three-lead electrocardiogram (ECG) without increasing the number of channels and electrodes in a commercially available two-channel Holter recorder was devised. On channel 1, a V5-like lead (CM5 lead) was recorded for 24 consecutive hours. On channel 2, the device could switch continuously between a V2-like lead (CM2 lead) and a II- or III- or a VF-like lead (CMf lead) every 30 sec. Fifty eight patients with angina pectoris were studied using this new device. There were 2 patients with variant angina pectoris, one of whom showed ST elevation in the CM2 lead coupled with ST depression in the CMf lead and the other ST elevation in the CMf lead coupled with ST depression in the CM2 lead. The number of patients having ST depression confined to the CM5 lead only, CM2 lead only and CMf lead only was 17, 2 and 3, respectively. In 41 patients, 127 transient episodes of ischemic type ST changes were observed during daily activity. Only 35 (28%) of these episodes were associated with anginal symptoms and the remaining 92 episodes occurred unrelated to such symptoms. Accordingly, 3-lead Holter monitoring using this device is useful, particularly for the detection of variant angina, and makes it less likely for asymptomatic ischemic ST changes to be overlooked as compared to the 2-lead conventional Holter monitoring system.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of diagnostic value using a small, single channel, P-wave centric sternal ECG monitoring patch with a standard 3-lead Holter system over 24 hours.

BACKGROUND To compare simultaneous recordings from an external patch system specifically designed to ensure better P-wave recordings and standard Holter monitor to determine diagnostic efficacy. Holter monitors are a mainstay of clinical practice, but are cumbersome to access and wear and P-wave signal quality is frequently inadequate. METHODS This study compared the diagnostic efficacy of th...

متن کامل

Comparison of Digital 12-Lead ECG and Digital 12-Lead Holter ECG Recordings in Healthy Male Subjects: Results from a Randomized, Double-Blinded, Placebo-Controlled Clinical Trial.

BACKGROUND Electrocardiogram (ECG) variability is greatly affected by the ECG recording method. This study aims to compare Holter and standard ECG recording methods in terms of central locations and variations of ECG data. METHODS We used the ECG data from a double-blinded, placebo-controlled, randomized clinical trial and used a mixed model approach to assess the agreement between two method...

متن کامل

Continuous Electrocardiography in Dogs and Cats

A new electrocardiogram (ECG) was started in 1961 when J. Norman Holter introduced a system to record the ECG of a patient during their activities for long periods of time. This method was identified as a method of continuous electrocardiography (CE), long-term electrocardiogram, dynamic electrocardiography, ambulatory electrocardiographic, or simply Holter. In subsequent years, the development...

متن کامل

A Unified Framework for Delineation of Ambulatory Holter ECG Events via Analysis of a Multiple-Order Derivative Wavelet-Based Measure

In this study, a new long-duration holter electrocardiogram (ECG) major events detection-delineation algorithm is described which operates based on the false-alarm error bounded segmentation of a decision statistic with simple mathematical origin. To meet this end, first three-lead holter data is pre-processed by implementation of an appropriate bandpass finite-duration impulse response (FIR) f...

متن کامل

ثبت دگرسویی آستانه‌های پاسخ پایدار شنوایی

    Background & Aim:Auditory steady�state response (ASSR) is an oscillation in the electrical potential recorded from the scalp. In this study, the possible effects of shifting the response recording channel on 40Hz ASSR thresholds and their recording times were evaluated and compared.Patients and Method:In this cross-sectional�study, 30 subjects with normal hearing (thresholds of 500 to 4000 ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Japanese heart journal

دوره 29 5  شماره 

صفحات  -

تاریخ انتشار 1988