Analytical artifacts in hematocrit measurements by whole-blood chemistry analyzers.
نویسندگان
چکیده
Compact analyzers suited to near-patient testing estimate hematocrit by measuring the conductivity of undiluted blood. We evaluated the accuracy of hematocrit determination of one such analyzer (Instrumentation Laboratory BGE analyzer) against an automated cell counter (EPC) and packed cell volume (PCV) microhematocrit. When specimens (n = 34) from outpatient and ward patients were analyzed with all three methods, the BGE analyzer correlated well with both EPC and PCV hematocrit determinations (BGE = 1.00 PCV + 0.3%, S(y)/x = 2.0%), suggesting that all three methods are similar in performance for most patients. However, a patient with increased plasma osmolality showed significant decreases in BGE and PCV hematocrits relative to the EPC method. The differences in hematocrit measurements could be reproduced by adding solutes to blood in vitro or by modifying the plasma osmolality of rats in vivo. Samples from patients undergoing cardiac surgery, whose blood had large changes in protein concentration, showed discrepancies between hematocrits by conductivity and other methods; similar effects could be produced by changes in protein concentration or in vitro addition of polyethylene glycol. We conclude that conductivity measurements provide accurate hematocrit results for physiologically normal subjects but not for some intensive-care and surgical patients.
منابع مشابه
Portable blood gas and electrolyte analyzer evaluated in a multiinstitutional study.
A recently introduced blood gas/electrolyte analyzer (SenDx 100((R)), renamed ABL70) intended for point-of-care, near-patient, or stat laboratory use was evaluated simultaneously in four different institutions and compared with three different laboratory bench analyzers with respect to imprecision, inaccuracy (assessed by tonometry), and patient-sample analyses. The analyzer is equipped with a ...
متن کاملNew in vitro analytical approaches for clinical chemistry measurements in critical care.
The effective management of patients in intensive care units, operating rooms, and emergency rooms requires frequent measurement of a select group of analytes, preferably at or near the patient's bedside. Tests recognized as being essential for such management include blood gases and related variables (pH, pO2, pCO2, HCO3-, hematocrit/hemoglobin, O2 saturation), electrolytes (Na+, K+, Ca2+, Cl-...
متن کاملLactate measured in diluted and undiluted whole blood and plasma: comparison of methods and effect of hematocrit.
We evaluated a new analyzer that measures lactate in undiluted whole blood by direct (or undiluted) amperometry [Nova Stat Profile 7 Analyzer (SP7); Nova Biomedical, Waltham, MA] by comparing it with two other analyzers, one for measuring lactate in whole blood by indirect (or diluted) amperometry [Model 2300; Yellow Springs Instrument Co. (YSI), Yellow Springs, OH] and another for measuring la...
متن کاملTwo whole-blood multi-analyte analyzers evaluated.
We evaluated two multi-analyte analyzers, the NOVA Stat Profile 1 (SP 1) and the NOVA Stat Profile 5 (SP 5). The SP 1 measures pH, pCO2, pO2, sodium, potassium, ionized calcium, and hematocrit in heparinized whole blood; the SP 5 determines all these analytes, plus chloride (not evaluated because it was unavailable at the time this study was initiated) and glucose. Interassay precision for pH, ...
متن کاملMarked interference of hyperglycemia in measurements of mean (red) cell volume by Technicon H analyzers.
Severe hyperglycemia can result in falsely high results for mean cell (erythrocyte) volume (MCV), which will also cause false results for erythrocyte indices calculated on the basis of MCV. Falsely high MCV results were obtained with the Technicon H1 and H2 analyzers and (to a lesser extent) with the Coulter T660. The H analyzers were more susceptible to this interference than was the Coulter T...