SU-E-I-18: Variability of Physiological Parameters Estimated by AATH and MTK Models in DCE-MRI.
نویسندگان
چکیده
PURPOSE To assess the accuracy and precision of physiological parameters estimated by the modified Tofts and Kermode (mTK) model and the adiabatic approximation to the tissue homogeneity (AATH) model in dynamic contrast enhanced (DCE) MRI. METHODS Computer simulations were performed using the arterial input function (AIF) from Parker et al., and the multiple indicator, multiple path, indicator dilution 4 region (MMID4) model for simulating the tissue concentration time curve. A set of physiological parameters, simulating a breast tumor, was selected as the input to the MMID4. The output was then converted to signal time curve using SPGR signal equation. Four levels of Gaussian noise, corresponding to SNRs of 100, 50, 20 and 10, were added to the signal time curves, with 1000 iterations each. These curves were then transferred back to concentration time curves on which mTK and AATH models were applied for fitting. For AATH model the mean transit time (tau) was held as a fixed parameter ranged from 2 to 10 s, and the final solution was selected based on minimizing the root mean square error. RESULTS For common parameters obtained by both models (Ktrans, Ve, Vp), AATH provided better accuracy, which agreed with the literatures, whereas mTK resulted in superior precision. As expected, greater coefficient of variation (CV) was found with smaller SNR in all cases. For the parameters that could only be obtained with the AATH model, the CVs were less than 10% for F, E and PS, and around 20% for tau, at the SNR level of 20. CONCLUSIONS Using the MMID4 model for data simulation, this work found that AATH model was more accurate but less precise for estimating physiological parameters as compared with mTK model. The AATH model was able to separate blood flow and permeability estimates with reasonable errors and variations.
منابع مشابه
Purpose:To assess the accuracy and precision of physiological parameters estimated by the modified Tofts and Kermode (mTK) model and the adiabatic approximation to the tissue homogeneity (AATH) model in dynamic contrast enhanced (DCE) MRI
ID: 18257 Title: Variability of Physiological Parameters Estimated by AATH and MTK Models in DCE-MRI Purpose:To assess the accuracy and precision of physiological parameters estimated by the modified Tofts and Kermode (mTK) model and the adiabatic approximation to the tissue homogeneity (AATH) model in dynamic contrast enhanced (DCE) MRI. Methods:Computer simulations were performed using the ar...
متن کاملComparison of the Kinetic Parameters Estimated with Different Numerical Methods in Dce-mri
Introduction: Dynamic contrast enhanced MRI (DCE-MRI) has been shown its ability to noninvasively assess characterization of tumor by the kinetic parameters, such as volume transfer constant (K) and rate constant (kep). The Tofts and Kermode (TK) model [1] and modification of Tofts and Kermode (mTK) model [2] are both popular pharmacokinetic models. Nonlinear least-squares (NLSQ) method is ofte...
متن کاملTemporal resolution and SNR requirements for accurate DCE-MRI measurement of microvascular blood flow and permeability using the AATH model
Introduction: Dynamic contrast-enhanced MRI has been used in conjunction with tracer kinetics modelling in a wide range of tissues for treatment monitoring, oncology drug development and investigation of disease processes. Accurate measurement of model parameters relies on high quality data, and as model complexity increases to allow measurement of more physiological parameters, the data qualit...
متن کاملWater-Exchange-Modified Kinetic Parameters from Dynamic Contrast-Enhanced MRI as Prognostic Biomarkers of Survival in Advanced Hepatocellular Carcinoma Treated with Antiangiogenic Monotherapy
BACKGROUND To find prognostic biomarkers in pretreatment dynamic contrast-enhanced MRI (DCE-MRI) water-exchange-modified (WX) kinetic parameters for advanced hepatocellular carcinoma (HCC) treated with antiangiogenic monotherapy. METHODS Twenty patients with advanced HCC underwent DCE-MRI and were subsequently treated with sunitinib. Pretreatment DCE-MRI data on advanced HCC were analyzed usi...
متن کاملThe Effects of Locally Estimated Arterial Input Functions on Pharmacokinetic Parameters in DCE-MRI
Introduction: Dynamic contrast-enhanced MRI (DCE-MRI) is physiological imaging tool used clinically to aid the diagnosis and treatment monitoring of a variety of diseases. Pharmacokinetic parameters can be estimated by fitting DCE-MRI data to one of many mathematical models. The two-compartment model used here describes the concentration of contrast agent (CA) in tissue with respect to three pa...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Medical physics
دوره 39 6Part4 شماره
صفحات -
تاریخ انتشار 2012