Spatial and Temporal Characteristics of Insulator Contaminations Revealed by Daily Observations of Equivalent Salt Deposit Density

نویسندگان

  • Ling Ruan
  • Ge Han
  • Zhongmin Zhu
  • Miao Zhang
  • Wei Gong
چکیده

The accurate estimation of deposits adhering on insulators is of great significance to prevent pollution flashovers which cause huge costs worldwide. Researchers have developed sensors using different technologies to monitor insulator contamination on a fine time scale. However, there is lack of analysis of these data to reveal spatial and temporal characteristics of insulator contamination, and as a result the scheduling of periodical maintenance of power facilities is highly dependent on personal experience. Owing to the deployment of novel sensors, daily Equivalent Salt Deposit Density (ESDD) observations of over two years were collected and analyzed for the first time. Results from 16 sites distributed in four regions of Hubei demonstrated that spatial heterogeneity can be seen at both the fine and coarse geographical scales, suggesting that current polluted area maps are necessary but are not sufficient conditions to guide the maintenance of power facilities. Both the local emission and the regional air pollution condition exert evident influences on deposit accumulation. A relationship between ESDD and PM10 was revealed by using regression analysis, proving that air pollution exerts influence on pollution accumulations on insulators. Moreover, the seasonality of ESDD was discovered for the first time by means of time series analysis, which could help engineers select appropriate times to clean the contamination. Besides, the trend component shows that the ESDD increases in a negative exponential fashion with the accumulation date (ESDD = a - b × exp(-time)) at a long time scale in real environments.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Analysis of Flashover Voltages of Disc Type Insulator under Artificial Pollution Condition (TECHNICAL NOTE)

Through this paper work we have analyzed the effect of different contaminants on the flashover by creating artificial pollution condition, considering the natural condition where more than one salt as contaminant deposits on the surface of insulator at a time, under the wet condition that cause flow of highly leakage current, that leads to flashover. We choses the mixture of different salts, so...

متن کامل

Impact of Pollution Location on Time and Frequency Characteristics of Leakage Current of Porcelain Insulator String under Different Humidity and Contamination Severity

One of the important factors influencing outdoor insulators performance is pollution phenomenon. The pollution, especially during humidity condition, reduces superficial resistance of insulator and lead to a flow of Leakage Currents (LC) on the insulator surface, which may result in total flashover. The LC characteristics are affected by parameters such as nature and severity of pollution. Loca...

متن کامل

A Comparative Study on Contamination Deposited Characteristics of ±800kV DC Line Insulators

This report describes the natural contamination test results of ±800kV line insulators at high altitudes. Natural exposure tests with -816kV DC voltage energization were carried out at National Engineering Laboratory for UHV Engineering Technology (Kunming).The results showed that the strain type and V-type insulator strings show a lighter pollution and the insulators with a better aerodynamic ...

متن کامل

Evaluating the Effects of Climate Change on Salt Crusts Using Remote Sensing (A Case Study of Sabzevar Playa)

In this study, five sequences of Landsat sensors including MSS, TM, ETM+ and OLI at unequal intervals spanning 42 years between 1973 and 2015, were analyzed to investigate the spatial and temporal variation of salt crusts in Sbzevar playa, central Iran. Landsat satellite imageries and ASTER digital elevation model were prepared, and spatial-temporal analyses were carried out in ENVI and GIS. Fu...

متن کامل

Comparison of adaptive techniques for the prediction of the equivalent salt deposit density of medium voltage insulators

One of the main reasons that flashover can occur in distribution lines is the sea salt contamination of medium voltage insulators. Equivalent salt deposit density (ESDD) expresses the contamination level of insulators and is used as the main criterion for scheduling the maintenance (washing) of insulators. In this paper two different adaptive techniques, a multi model partitioning filter (MMPF)...