Precordial Doppler probe placement for optimal detection of venous air embolism during craniotomy.
نویسندگان
چکیده
Verification of appropriate precordial Doppler probe position over the anterior chest wall is crucial for early detection of venous air embolism. We studied responses to normal saline (NS) and carbon dioxide (CO2) test injections at various probe locations during elective craniotomy. All patients received four IV injections (10 mL of NS and 1 mL of CO2 via central and peripheral venous catheters). Doppler sounds were simultaneously recorded with two separate probes. In Group A, probes were placed in left and right parasternal positions. In Group B, the left probe was intentionally malpositioned as far laterally over the left precordium as was compatible with an audible signal. In Group A (n = 23), a left parasternal Doppler signal was easily obtainable in 23 of 23 patients, versus 18 of 23 patients for the right parasternal probe (P < 0.05). In Group B (n = 17), central CO2 injection yielded a positive right parasternal response rate of 88% compared with 29% over the far left precordium (P < 0.015), where central NS injections yielded a 76% response rate (P < 0.015 versus central CO2 injection). Left parasternal placement is at least as sensitive to clinical venous air embolism events as right parasternal placement. Peripheral saline injection represents a viable alternative (83% response rate). Vigorous central injection of 10 mL of NS however, risks false positive verification of left lateral precordial probe placement.
منابع مشابه
Comparison of a transesophageal and precordial ultrasonic Doppler sensor in the detection of venous air embolism.
Early detection and prompt treatment are important factors that limit morbidity and mortality secondary to venous air embolism (VAE) (1). The precordial Doppler ultrasonic sensor and transesophageal echocardiograph are the two most sensitive monitors currently available to detect VAE (2,3). The Aloka SSD-870 transesophageal echocardiograph is equipped with a Doppler sensor at the distal end of ...
متن کاملThe Inter-Mammary Sticky Roll: A Novel Technique for Securing a Doppler Ultrasonic Probe to the Precordium for Venous Air Embolism Detection
Venous air embolism is a devastating and potentially life-threatening complication that can occur during neurosurgical procedures. We report the development and use of the "inter-mammary sticky roll," a technique to reliably secure a precordial Doppler ultrasonic probe to the chest wall during neurosurgical cases that require lateral decubitus positioning. We have found that this noninvasive te...
متن کاملAir embolism during craniotomy in the seated position: a comparison of methods for detection.
A case of air embolism sufficient to cause cardiovascular collapse is reported. This occurred during biopsy of the trigeminal nerve with the patient in the seated position. The use of an end-tidal carbon-dioxide monitor was a better indicator than a precordial doppler of the embolic problem. It allowed rapid detection and prompt resuscitation to be carried out. Air embolism is a significant and...
متن کاملEffect of positive end-expiratory pressure on the incidence of venous air embolism and on the cardiovascular response to the sitting position during neurosurgery.
We have studied prospectively the effect of 10 cm H2O of PEEP on the incidence of venous air embolism and on the cardiovascular response to change from the supine to the seated position in a large neurosurgical population. Patients were allocated randomly to receive either PEEP (10 cm H2O, n = 45) or conventional (control, n = 44) ventilation. Cardiovascular and respiratory variables were measu...
متن کاملVenous Air Embolism during Elective Craniotomy for Parasagittal Meningioma.
We report a case of a 59 year old man who developed venous air embolism (VAE) during an elective craniotomy for parasagittal meningioma resection. The surgery was done in the supine position with slightly elevated head position. VAE was provisionally diagnosed by sudden decreased in the end tidal carbon dioxide pressure from 34 to 18 mmHg, followed by marked hypotension and atrial fibrillation....