Performance Evaluation of New Generation CdZnTe Detectors for Safeguards Applications

نویسندگان

  • V. Ivanov
  • J. Mintcheva
  • A. Berlizov
  • A. Lebrun
چکیده

Cadmium zinc telluride detectors (CdZnTe) have found a wide application in non-destructive assay measurements in the IAEA’s verification practice. It is because of their form factor, usability, sensitivity and good spectral characteristics that they are extensively used for fresh and spent fuel attribute test measurements. Until now, the series of CdZnTe detectors utilized in the IAEA have covered the range of 5 mm, 20 mm, 60 mm and 500 mm of sensitive volume. Recently, new CdZnTe detectors with improved spectroscopic characteristics and significantly bigger active volume have become available, owing to advances in crystal and detector manufacturing and signal processing technologies. The distinctive feature of this new technological development is the application of a low-intensity monochromatic optical stimulation with infrared (IR) light. The use of IR illumination with a properly chosen wavelength close to the absorption edge of the CdZnTe can significantly improve the performance of the detectors. Recognizing potential benefits of these detectors in safeguards applications, the IAEA has performed an evaluation of their performance characteristics. Under evaluation were several new detectors with sensitive volumes of 500 mm, 1500 mm and 4000 mm, as well as all-in-one 60 mm, 500 mm and 1500 mm integrated micro-spectrometers available from RITEC, Latvia. In addition to the standard performance characteristics, such as energy resolution, peak shape, efficiency, linearity, throughput and temperature stability, the potential use of the detectors for safeguards specific measurements, such as uranium enrichment with infinite thickness method, was of particular interest. The paper will describe the advances in the CdZnTe detector technology and present the results of their performance evaluation.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Advanced Readout ASICs for Multielement CZT Detectors

A generation of high performance front-end and read-out ASICs customized for highly segmented CdZnTe sensors is presented. The ASICs, developed in a multi-year effort at Brookhaven National Laboratory, are targeted to a wide range of applications including medical, safeguards/security, industrial, research, and spectroscopy. The front-end multichannel ASICs provide high accuracy low noise pream...

متن کامل

Direct Conversion CdZnTe and CdTe Detectors for Digital Mammography

Hybrid CdZnTe and CdTe pixel detector arrays with 50 50 micron pixel sizes that convert x-rays directly into charge signals are under development at NOVA for applications to digital mammography. CdZnTe and CdTe have superior x-ray quantum efficiency compared to either emulsion-based film, phosphor-based detectors or other low-Z, solid-state detectors such as silicon. In this paper, latest resul...

متن کامل

Progress in the Development of CdTe and CdZnTe Semiconductor Radiation Detectors for Astrophysical and Medical Applications

Over the last decade, cadmium telluride (CdTe) and cadmium zinc telluride (CdZnTe) wide band gap semiconductors have attracted increasing interest as X-ray and gamma ray detectors. Among the traditional high performance spectrometers based on silicon (Si) and germanium (Ge), CdTe and CdZnTe detectors show high detection efficiency and good room temperature performance and are well suited for th...

متن کامل

Transport Properties and Performance of Cdznte Strip Detectors

| We report on recent tests and computer simulations of a sub-millimeter pitch CdZnTe strip detector under study as a prototype imaging spectrometer. This paper presents new measurements and new analyses of previous measurements of the CdZnTe transport properties for this prototype and resolves previously reported quantitative discrepancies. Measurements of charge signals produced by-rays are u...

متن کامل

Coplanar grid CdZnTe detectors for space science applications

The characteristics and performance for two of the latest coplanar grid CdZnTe detectors, which use the thirdgeneration coplanar grid design, will be discussed. These detectors, with dimensions of 1.5×1.5×0.9 cm and 1.5×1.5×0.95 cm, were fabricated by Baltic Scientific Instruments, Ltd., using crystals from Yinnel Tech, Inc. The high μeτe product measured for these crystals will lead to improve...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014