Fixation of subtrochanteric extending/derotational femoral osteotomies with the Locking Compression Plate in ambulatory neuro-orthopaedic patients.

نویسندگان

  • Mathias Haefeli
  • Hanspeter Huber
  • Stefan Dierauer
  • Leonhard E Ramseier
چکیده

PURPOSE Patients with neuro-orthopaedic disorders often develop hip flexion contractures or rotational hip deformities. Increasing deformities impair the already diminished walking abilities and proximal femoral osteotomies are often performed to maintain/improve walking abilities. Fixation of the osteotomies with condylar plates has been successfully used but does often not allow immediate postoperative full weight bearing. To avoid a substantial postoperative rehabilitation deficit and additional bone loss due to inactivity, a postoperative treatment with full weight bearing is, therefore, wishful. Newer fixed-angled implants with stronger anchoring in osteopenic bone might fit these demands. The objective of this study was to evaluate bone healing and the complication rate after proximal extending and/or derotational femoral osteotomy fixed with 3.5/4.5 Locking Compression Plate (LCP; Synthes(®)) and postoperative full weight bearing in ambulatory neuro-orthopaedic patients. METHODS Fifteen ambulatory neuro-orthopaedic patients (12 cerebral palsy [CP], 1 trisomy 21, 2 hemiparesis) with a mean age of 13.7 years (range 7-22) with hip flexion contractures and/or rotational deformities underwent subtrochanteric (n = 26) osteotomy between July 2004 and October 2007. All patients were allowed to bear their full weight postoperatively. We investigated the fusion rate, implant failure, and general complication rate until union had occurred. RESULTS Fourteen patients (mean weight 42.0 kg [range 21.8-59]) uneventfully achieved solid fusion. One patient (19 years of age, 73 kg) needed revision surgery due to implant failure with consecutive varus deformity and achieved solid fusion after the second intervention. Besides one superficial wound infection, no other complications occurred. CONCLUSIONS Subtrochanteric extending and/or derotational osteotomies fixed with an LCP are a reliable procedure in neuro-orthopaedic patients. Most patients can be treated with early postoperative full weight bearing. However, in heavier patients, possible implant failure must be considered.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Proximal femoral locking compression plate for proximal femoral fractures.

PURPOSE To review short-term outcomes of proximal femoral locking compression plate (PF-LCP) fixation for proximal femoral fractures in terms of postoperative complications and failure rates. METHODS Medical records of 21 men and 5 women aged 22 to 85 (mean, 49.7) years who underwent internal fixation with the PF-LCP for proximal femoral fractures were reviewed. Younger patients (mean age, 38...

متن کامل

Subtrochanteric osteotomy for femoral mal-torsion through a surgical dislocation approach

UNLABELLED Missed torsional femur deformities may contribute to reasons for failure after open and more likely arthroscopic hip preservation surgery. A number of surgical approaches have been described for addressing torsion abnormalities. This report describes a subtrochanteric osteotomy technique in a consecutive series of patients with complex hip pathologies, for which intertrochanteric ost...

متن کامل

The Outcome in Early Cases of Treatment of Subtrochanteric Fractures with Proximal Femur Locking Compression Plate

ABSTRACT The objective of this study was to evaluate the outcome in early treatment of subtrochanteric fractures with proximal femur locking compression plate (PF-LCP).The patients included in this study were those with subtrochanteric fractures (AO type 32A-C) treated with PF-LCP (Synthes) between Jan 2009 and Jun 2011. The patient characteristics and details of clinical conditions were obtain...

متن کامل

A Pitfall in Fixation of Distal Humeral Fractures with Pre-Contoured Locking Compression Plate

Anatomically precontoured locking plates are intended to facilitate the fixation of articular fractures and particularly those associated with osteoporosis. Fractures of the distal humerus are relatively uncommon injuries where operative intervention can be exceptionally challenging. The distal humeral trochlea provides a very narrow anatomical window through which to pass a fixed-angle locking...

متن کامل

Supracondylar Osteotomy in Valgus Knee: Angle Blade Plate Versus Locking Compression Plate

  Background: There are few studies comparing the biomechanical properties of angled blade plate and locking compression plates in supracondylar osteotomy. In the current randomized study, we prospectively compared the clinical and radiological outcomes of supracondylar osteotomy using these two plates. Methods: Forty patients with valgus knee malalignment were randomly assigned to two equal nu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of children's orthopaedics

دوره 4 5  شماره 

صفحات  -