Investigating interferences of a whole-blood point-of-care creatinine analyzer: comparison to plasma enzymatic and definitive creatinine methods in an acute-care setting.

نویسندگان

  • Joely A Straseski
  • Martha E Lyon
  • William Clarke
  • Jeffrey A Dubois
  • Lois A Phelan
  • Andrew W Lyon
چکیده

BACKGROUND Although measurement of whole-blood creatinine at the point of care offers rapid assessment of renal function, agreement of point-of-care (POC) results with central laboratory methods continues to be a concern. We assessed the influence of several potential interferents on POC whole-blood creatinine measurements. METHODS We compared POC creatinine (Nova StatSensor) measurements with plasma enzymatic (Roche Modular) and isotope dilution mass spectrometry (IDMS) assays in 119 hospital inpatients. We assessed assay interference by hematocrit, pH, pO(2), total and direct bilirubin, creatine, prescribed drugs, diagnosis, red blood cell water fraction, and plasma water fraction. RESULTS CVs for POC creatinine were 1.5- to 6-fold greater than those for plasma methods, in part due to meter-to-meter variation. Regressioncomparison of POC creatinine to IDMS results gave a standard error (S(y|x)) of 0.61 mg/dL (54 μmol/L), whereas regression of plasma enzymatic creatinine to IDMS was S(y|x) 0.16 mg/dL (14 μmol/L). By univariate analysis, bilirubin, creatine, drugs, pO(2), pH,plasma water fraction, and hematocrit were not found to contribute to method differences. However, multivariate analysis revealed that IDMS creatinine, red blood cell and plasma water fractions, and hematocrit explained 91.8% of variance in POC creatinine results. CONCLUSIONS These data suggest that whole-blood POC creatinine measurements should be used with caution. Negative interferences observed with these measurements could erroneously suggest adequate renal function near the decision threshold, particularly if estimated glomerular filtration rate is determined. Disparity between whole-blood and plasma matrices partially explains the discordance between whole-blood and plasma creatinine methods.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Piccolo® Comprehensive Metabolic Reagent Disc

chemistry analyzer, is intended to be used for the in vitro quantitative determination of alanine aminotransferase (ALT), albumin, alkaline phosphatase (ALP), aspartate aminotransferase (AST), calcium, chloride, creatinine, glucose, potassium, sodium, total bilirubin, total carbon dioxide, total protein, and blood urea nitrogen (BUN) in heparinized whole blood, heparinized plasma, or serum in a...

متن کامل

Evaluation of the i-STAT Portable Clinical Analyzer for point-of-care blood testing in the intensive care units of a university children's hospital.

We evaluated the analytical performance of the i-STAT Portable Clinical Analyzer (PCA), a point-of-care testing system consisting of a hand-held analyzer and single-use cartridges that measure different panels of electrolytes, metabolites, blood gases, and hematocrit in 65-100 microl of blood. Our objective was to determine whether PCA measurements at the bedside of patients in the neonatal and...

متن کامل

The Effects of Lipid Emulsion on the Improvement of Glasgow Coma Scale and Reduction of Blood Glucose Level in the Setting of Acute Non-Local Drug Poisoning: A Randomized Controlled Trial

Background: Our aim was to evaluate the effect of intravenous intralipid administration as an antidote on the poisoned patients' Glasgow Coma Scale (GCS), hemodynamic parameters, arterial blood gas analysis, and routine metabolic profile tests (i.e. urea, glucose, sodium, and potassium) in the setting of non-local anesthetic drug overdose. Methods: In this randomized controlled trial, a tota...

متن کامل

Assessment of the Nova StatSensor whole blood point-of-care creatinine analyzer for the measurement of kidney function in screening for chronic kidney disease.

BACKGROUND Point-of-care testing for creatinine using a fingerprick sample and resultant estimated glomerular filtration rate has potential for screening for chronic kidney disease in community settings. This study assessed the applicability of the Nova StatSensor creatinine analyzer for this purpose. METHODS Fingerprick samples from 100 patients (63 renal, 37 healthy volunteers; range 46-962...

متن کامل

Determining an accurate method to estimate GFR in renal transplant recipients with stable serum creatinine levels

Introduction:Detecting renal allograft dysfunction early will allow timely diagnosis and treatment. There is no objective recommendation by national kidney societies for glomerular filtration rate (eGFR) estimation in post-transplant setting. 99mTc-DTPA Technetium-99m Diethylene triamine penta acetic acid) renogram can identify early renal dysfunction much before ser...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry

دوره 57 11  شماره 

صفحات  -

تاریخ انتشار 2011