Detection of hepatocellular carcinoma: comparison of T2-weighted breath-hold fast spin-echo sequences and high-resolution dynamic MR imaging with a phased-array body coil.
نویسندگان
چکیده
The purpose of our study was to compare T2-weighted breath-hold fast spin-echo sequence (BHFSE) and high-resolution dynamic MR imaging (HR-DMRI) in the detection of hepatocellular carcinoma (HCC). Short and long T2-weighted BHFSE sequences and biphasic HR-DMRI including arterial-dominant and delayed phase images with a phased-array body coil were performed in 30 consecutive patients with 37 HCCs. The lesion-to-liver contrast-to-noise ratio (CNR) was quantitatively measured. The lesion conspicuity and delineation was qualitatively rated according to a four-point scale. The lesion-to-liver CNR was highest with the arterial-dominant phase HR-DMRI and was significantly higher than those obtained with both short and long T2-weighted BHFSE and those obtained with unenhanced and delayed HR-DMRI. The CNR obtained with short T2-weighted BHFSE was significantly higher than those obtained with long T2-weighted BHFSE and with unenhanced and delayed HR-DMRI. The sensitivity for the sequences was 78.4% (29/37) for short T2-weighted BHFSE, 67.6% (25/37) for long T2-weighted BHFSE, 37.8% (14/37) for unenhanced HR-DMRI, 97.3% (36/37) for arterial-dominant phase HR-DMRI, and 43.2% (16/37) for delayed HR-DMRI. The sensitivity of serial dynamic MR imaging combined with unenhanced, arterial-dominant phase imaging and delayed phase imaging was 100% (37/37). The score in the qualitative analysis of the lesion conspicuity and delineation was highest for the arterial-dominant phase HR-DMRI and was significantly higher than that for the short T2-weighted BHFSE. The score for the short T2-weighted BHFSE was significantly higher than that for the long T2-weighted BHFSE and that for the unenhanced HR-DMRI. Arterial-dominant phase HR-DMRI is superior to the T2-weighted BHFSE technique, and also HR-DMRI combined with unenhanced, arterial-dominant and delayed phases is the most sensitive technique in the detection of HCC.
منابع مشابه
Optimal Pulse Sequence for Ferumoxides-Enhanced MR Imaging Used in the Detection of Hepatocellular Carcinoma: A Comparative Study Using Seven Pulse Sequences
OBJECTIVE To identify the optimal pulse sequence for ferumoxides-enhanced magnetic resonance (MR) imaging in the detection of hepatocelluar carcinomas (HCCs). MATERIALS AND METHODS Sixteen patients with 25 HCCs underwent MR imaging following intravenous infusion of ferumoxides. All MR studies were performed on a 1.5-T MR system, using a phased-array coil. Ferumoxides (Feridex IV) at a dose of...
متن کاملDetection of focal hepatic lesions with MR imaging: prospective comparison of T2-weighted fast spin-echo with and without fat suppression, T2-weighted breath-hold fast spin-echo, and gadolinium chelate-enhanced 3D gradient-recalled imaging.
OBJECTIVE The purpose of this study was to compare breath-hold three-dimensional (3D) rapid gradient-echo (GRE) MR imaging obtained before and after gadolinium chelate injection with T2-weighted fast spin-echo and T2-weighted breath-hold fast spin-echo (BHFSE) MR imaging in the detection of focal hepatic masses. SUBJECTS AND METHODS Fifty-three patients with 108 focal hepatic masses had, pros...
متن کاملProstate Cancer: Added Value of Subtraction Dynamic Imaging in 3T Magnetic Resonance Imaging with a Phased-array Body Coil
PURPOSE To determine the added value of dynamic subtraction magnetic resonance (MR) imaging for the localization of prostate cancer. MATERIALS AND METHODS We examined 21 consecutive patients who underwent MR imaging in 3T unit with a phased-array body coil and then had radical prostatectomy. After T2-weighted fast spin-echo imaging, we performed a contrast-enhanced dynamic 3D gradient-echo im...
متن کاملSSFSE MR Imaging of Focal Hepatic Lesions
With improvements in pulse sequence design and gradient amplifiers complete breath-hold MR imaging of the liver is possible enabling rapid evaluation, which is relatively free of motion artifacts. The combination of Single Shot Fast Spin-Echo (SSFSE) and Fast Multiplanar Spoiled Gradient-Echo(FMSPGR) sequences provide both breath-hold T2and TI-weighted non-contrast images, as well as multiphase...
متن کاملLow-cost high-resolution fast spin-echo MR of acoustic schwannoma: an alternative to enhanced conventional spin-echo MR?
PURPOSE To determine whether unenhanced high-resolution T2-weighted fast spin-echo MR imaging provides an acceptable and less expensive alternative to contrast-enhanced conventional T1-weighted spin-echo MR techniques in the diagnosis of acoustic schwannoma. METHODS We reviewed in a blinded fashion the records of 25 patients with pathologically documented acoustic schwannoma and of 25 control...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of magnetic resonance imaging : JMRI
دوره 9 2 شماره
صفحات -
تاریخ انتشار 1999