WFPC2 Flatfields with Reduced Noise
نویسندگان
چکیده
We examine the noise contributed by the WFPC2 flatfields during normal calibration, and provide new low-noise flats for 41 filters. Highly exposed science images (>20,000 electrons per pixel) will show significant noise reduction if these new flats are used; this is especially true for images on the PC1 chip. For some ultraviolet filters a significant improvement occurs even for much lower exposure levels. Potential photometric issues are also discussed. The new flats are available in the HST data archive as “correction” images which observers can multiply into calibrated science data (i.e. data which have already calibrated with the normal flatfields) to obtain the noise reduction. These corrections may be incorporated in the normal pipeline flatfields at some future date for selected filters.
منابع مشابه
WFPC2 Flatfields with Reduced Noise and an Anomaly of Filter FQCH4N-D
The transmission of the filter FQCH4N-D varies by 20 percent across the filter while the mean wavelength shifts by 3 nm. For objects with a flat spectrum across the main bandpass (889–897 nm), the flatfielding removes the spatial variations except for the outer corner, for which we give the necessary photometric correction. On the other hand, for objects with steep spectral features within the ...
متن کاملNicmos Observations of the Hubble Deep Field: Observations, Data Reduction, and Galaxy Photometry
This paper presents data obtained during the NICMOS Guaranteed Time Observations of a portion of the Hubble Deep Field. The data are in a catalog format similar to the publication of the original WFPC2 Hubble Deep Field Program (Williams et al. 1996). The catalog contains 342 objects in a 49.1 × 48.4 subfield of the total observed field, 235 of which are considered coincident with objects in th...
متن کاملWFC3 TV3 Testing: Quantum Yield in the UV
The gain for the integrated WFC3 UVIS-1’ flight detector has been computed using the mean-variance method on flatfields taken in a small set of UV filters. These gains are compared to the gain computed in the visible (F606W) in order to estimate the quantum yield for the UVIS-1’ detector. The measured quantum yields are 1.07, 1.08, 1.03, and 1.00 e-/ photon, for F218W, F225W, F275W, and F336W, ...
متن کاملA repository of precision flatfields for high resolution MDI continuum data
Abstract We describe an archive of high-precision MDI flat fields, that can be used to refine most MDI high resolution continuum data. The archive consists of many flat field images representing different time ranges over the full operating period of SOHO. The residual flatfield error on the standard level 1.5/1.8 calibrated continuum images represents a significant proportion (25-100%) of the ...
متن کاملWFPC2 Photometric Calibration
The updated absolute photometric calibration for WFPC2 yields typical uncertainties for bright sources below 2% for the photometric filter set and of about 3% for other filters between 400 and 800 nm. We present a quantitative characterization of some well-known WFPC2 non-linearities, the CTE error and the long vs. short anomaly, which allows a better estimate of their possible impact under a v...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -