A Modified Design for the Lykken Zinc Electrodes.

نویسندگان

  • S KAPLAN
  • G R FISHER
چکیده

As Lykken has so clearly demonstrated, careful choice of skin resistance electrodes is essential for accurate, artifact-free recording (1). The zinc electrodes he describes are of particular interest since they are electrically stable, simple to apply, and require less complicated circuitry than the lead-lead variety. The purpose of this note is to describe a modification of the zinc electrode which has the following advantages: (1) it is simpler to build; described by Lykken. Note, however that the electrodes must be cleaned with water and not with alcohol, since application of alcohol may lead to cracking the lucite body of the electrode. If the electrode is wiped with a tissue immediately after use, even water will rarely be necessary.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Modelling of Adsorption of Zinc and Silver Ions on Analcime and Modified Analcime Zeolites Using Central Composite Design

In this study, Response Surface Methodology (RSM) using Central Composite Design (CCD) was employed to optimize the conditions of independent variables (adsorption time and ion solution concentration) for the removal of Zinc (II) and Ag ions from the aqueous solutions using analcime and modified analcime zeolites (Fe-ANA and Ni-ANA) as efficient and low cost adsor...

متن کامل

Fabrication of Resistive E. coli Biosensor Based on ZnO Nanorods and Nanoparticles

In this paper, a biosensor has been fabricated using ZnO nanorods and nanoparticles to detect different concentrations of the E. coli bacteria. The innovation of this paper lies in design and fabrication of the resistive type E Coli bacteria sensor. To make this biosensors, printed circuit board based electrodes are designed and made in an interdigitated shape. Both hydrothermal and drop cast m...

متن کامل

Development of novel potentiometric sensors for determination of lidocaine hydrochloride in pharmaceutical preparations, serum and urine samples

This article is focused on the determination of lidocaine hydrochloride as a local anaesthetic drug. A potentiometric method based on modified screen-printed and modified carbon paste ion-selective electrodes was described for the determination of lidocaine hydrochloride in different pharmaceutical preparations. It was based on potentiometric titration of lidocaine hydrochloride using modified ...

متن کامل

Development of novel potentiometric sensors for determination of lidocaine hydrochloride in pharmaceutical preparations, serum and urine samples

This article is focused on the determination of lidocaine hydrochloride as a local anaesthetic drug. A potentiometric method based on modified screen-printed and modified carbon paste ion-selective electrodes was described for the determination of lidocaine hydrochloride in different pharmaceutical preparations. It was based on potentiometric titration of lidocaine hydrochloride using modified ...

متن کامل

ارزیابی قابلیت افزایش عمر باتری‌های روی‌ـ نقره به‌وسیلۀ بهینه‌سازی فشار پرس به‌کاررفته در تولید الکترودهای نقره

In this study, effect of press pressure used in the production of silver electrodes on the life of zinc - silver oxide batteries was investigated. For this purpose, initially four Ag electrodes (positive plate) with composition of 95 wt% silver oxide, 4.9 wt% carbon powder and 0.1 wt% resin prepared by powder metallurgy method and the press pressures of 40, 60, 80 and 100 bar was applied. Then,...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Psychophysiology

دوره 1  شماره 

صفحات  -

تاریخ انتشار 1964