Performance of a direct detection camera for off-axis electron holography.

نویسندگان

  • Shery L Y Chang
  • Christian Dwyer
  • Juri Barthel
  • Chris B Boothroyd
  • Rafal E Dunin-Borkowski
چکیده

The performance of a direct detection camera (DDC) is evaluated in the context of off-axis electron holographic experiments in a transmission electron microscope. Its performance is also compared directly with that of a conventional charge-coupled device (CCD) camera. The DDC evaluated here can be operated either by the detection of individual electron events (counting mode) or by the effective integration of many such events during a given exposure time (linear mode). It is demonstrated that the improved modulation transfer functions and detective quantum efficiencies of both modes of the DDC give rise to significant benefits over the conventional CCD cameras, specifically, a significant improvement in the visibility of the holographic fringes and a reduction of the statistical error in the phase of the reconstructed electron wave function. The DDC's linear mode, which can handle higher dose rates, allows optimisation of the dose rate to achieve the best phase resolution for a wide variety of experimental conditions. For suitable conditions, the counting mode can potentially utilise a significantly lower dose to achieve a phase resolution that is comparable to that achieved using the linear mode. The use of multiple holograms and correlation techniques to increase the total dose in counting mode is also demonstrated.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Field Mapping in Semiconductors by Off-axis Electron Holography: From Devices to Graphene and Single Dopant Atoms

Off-axis electron holography is an electron microscopy-based technique that allows the electrostatic and magnetic fields in and around a specimen to be measured with nm-scale resolution. The continuous reduction in the size of semiconductor devices means that information about the distribution of strain fields and active dopants at a nanometre scale is required in order to understand how these ...

متن کامل

Electron Holography and Lorentz Microscopy of Magnetic Thin Films and Multilayers

A recently acquired 200-kV field emission gun transmission electron microscope equipped with a highmagnification Lorentz lens, an electrostatic biprism, and a slow-scan charge-coupled device (CCD) camera has been utilized for micromagnetic studies of ultrathin films and multilayers under relatively field-free conditions. For planview imaging of a thin Fe film and cross-sectional imaging of anis...

متن کامل

Hybridization of Off-Axis and In-line High-Resolution Electron Holography

Reconstruction of the complex-valued wave function that gives rise to the probability density of fast electrons in transmission electron microscopy (TEM) seems, at first glance, to be a solved problem. However, it is still challenging when considered more closely. In conventional TEM experiments, only the intensity (i.e., the square of the amplitude) of the wave function can be measured. Direct...

متن کامل

In Situ Biasing of Tapered Si-Ge NW Heterojunctions using Off-Axis Electron Holography

Heterojunction Si-Ge nanowires (NWs) have potential applications such as field effect transistors [1]. Knowledge of the active dopant concentration and distribution, and resultant built-in potential across the Si-Ge p-n junction under biasing conditions is important for improving device performance. Off-axis electron holography is an effective method to measure electrostatic potential with nano...

متن کامل

Noise and aliases in off-axis and phase-shifting holography.

We have compared the respective efficiencies of off-axis and phase-shifting holography in terms of noise and aliases removal. The comparison is made by analyzing holograms of a USAF target backlit with laser illumination, recorded with a charge-coupled device camera. We show that it is essential to remove the local oscillator beam noise, especially at low illumination levels.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Ultramicroscopy

دوره 161  شماره 

صفحات  -

تاریخ انتشار 2016