An etched track detector for short-term screening measurements of radon.
نویسندگان
چکیده
An etched track detector has been developed for use in screening or indicative measurements of radon in homes over an exposure period of 14 days. If the annual mean radon concentration estimated from screening detector results is within a factor of two of the UK radon Action Level (200 Bq m(-3)), the householder is told that the result is uncertain, and advice on whether the home is above or below the Action Level must be based on the result of a (standard) 90 day measurement. The screening detectors are always supplied to householders together with detectors to be exposed for 90 days, so that if the screening result is reported as being uncertain (within the range 100-400 Bq m(-3)), a long-term measurement in the home is already under way. Comparison of the results of the screening (14 day) and standard (90 day) detectors exposed in the same homes shows that reporting screening results in this way did not result in any householders being wrongly advised. Short-term measurements can therefore be offered in those circumstances where a householder needs a faster indication of radon levels in a property (for example a house sale), with the caveat that a 14 day exposure result within a factor of two of the Action Level requires a long-term measurement to confirm whether the dwelling is above or below the Action Level. A precautionary uncertainty range for use with charcoal detector measurements is also given (75-500 Bq m(-3)).
منابع مشابه
Measurement of Contemporary and Retrospective Radon Concentration in Ramsar Dwellings Using Polycarbonate Detector
The origins of radon gas are the amount of uranium decay in the soil that is released into space and through the interior gaps of buildings. Radon can enter the respiratory system and cause radiation hazards. Recently research has identified Radon as the second leading cause of lung cancer after cigarette smoking. The indoor concentration of Radon progeny is mentioned as an important issue reg...
متن کاملProton beam dosimetry by CR-39 track-etched detector
Background: High and intermediate energy protons are not able to form a track in a solid state nuclear track detector (SSNTD) directly. However, such tracks can be formed through secondary particles created during primary radiation nuclear reactions in a SSNTD. Materials and Methods: The protons with primary energies of 9.6 and 30 MeV available at the cyclotron accelerator with corresponding lo...
متن کاملCalibration and optimization of a low cost diffusion chamber for passive separated measurements of radon and thoron in soil by Lexan PC SSNTD
Background: Separate radon and thoron measurements in soil are very important in assessment of internal exposure due to inhalation of such radioactive gases. Materials and Methods: In this study, a low cost, small size, passive diffusion chamber has been developed for simple measurement of Radon-222 and Radon-220(Thoron) gases separately in soil. The diffusion chamber consists of two films and ...
متن کاملاندازه گیری غلظت گاز رادون در منازل مسکونی شهر گرگان
Background and purpose: Radon is a colorless inert gas which decay products are the main component of natural radioactive elements that are naturally produced in under layers of earth crust by decay of radium and uranium. It enters through buildings via gaps and cracks. Alpha particle emissions as a radon gas decay product can increase the incidence of lung cancer in human. Every person spends ...
متن کاملIndoor exposure assessment of radon in the elementary schools, Palestine
Background: Many public health agencies rank residential radon exposure as the second leading cause of lung cancer after cigarette smoking. It has been shown that the risk coefficient for lung cancer is higher for children than that for adults. Therefore, indoor radon measurements were carried out in the elementary schools of Tulkarem province, West Bank, Palestine. Materials and Methods: Two h...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of radiological protection : official journal of the Society for Radiological Protection
دوره 29 3 شماره
صفحات -
تاریخ انتشار 2009