Objective Amplitude of Accommodation Computed from Optical Quality Metrics Applied to Wavefront Outcomes

نویسندگان

  • Norberto López-Gil
  • Vicente Fernández-Sánchez
  • Larry N. Thibos
  • Robert Montés-Micó
چکیده

PURPOSE: We studied the accuracy and precision of 32 objective wavefront methods for finding the amplitude of accommodation obtained in 180 eyes. METHODS: Ocular accommodation was stimulated with 0.5 D steps in target vergence spanning the full range of accommodation for each subject. Subjective monocular amplitude of accommodation was measured using two clinical methods, using negative lenses and with a custom Badal optometer. RESULTS Both subjective methods gave similar results. Results obtained from the Badal optometer where used to test the accuracy of the objective methods. All objective methods showed lower amplitude of accommodation that the subjective ones by an amount that varied from 0.2 to 1.1 D depending on the method. The precision in this prediction also varied between subjects, with an average standard error of the mean of 0.1 D that decreased with age. CONCLUSIONS: Depth of field increases subjective of amplitude of accommodation overestimating the objective amplitude obtained with all the metrics used. The change in the negative direction of spherical aberration during accommodation increases the amplitude of accommodation by an amount that varies with age. (J Optom 2009;2:223-234 ©2009 Spanish Council of Optometry)

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determining the accommodative response from wavefront aberrations.

The purpose of this study was to evaluate some of the methods used to calculate objective refractions from wavefront aberrations, to determine their applicability for accommodation research. A wavefront analyzer was used to measure the ocular aberrations of 13 emmetropes and 17 myopes at distance, and 4 near target vergences: 2, 3, 4, and 5 D. The accommodative response was calculated using the...

متن کامل

Wave aberration of human eyes and new descriptors of image optical quality and visual performance.

The expansion of wavefront-sensing techniques redefined the meaning of refractive error in clinical ophthalmology. Clinical aberrometers provide detailed measurements of the eye's wavefront aberration. The distribution and contribution of each higher-order aberration to the overall wavefront aberration in the individual eye can now be accurately determined and predicted. Using corneal or ocular...

متن کامل

Refractive Surgery Feature Story

SEPTEMBER 2010 CATARACT & REFRACTIVE SURGERY TODAY EUROPE 35 T he introduction of wavefront-sensing techniques to ophthalmology has redefined the clinical meaning of refractive error. Now, all imperfections in the components and materials within the eye that cause light rays to deviate from their desired path are referred to as optical aberrations. Lower-order aberrations (defocus and astigmati...

متن کامل

Comparison of optical quality metrics to predict subjective quality of vision after laser in situ keratomileusis.

PURPOSE To compare wavefront-derived metrics to predict subjective quality of vision after laser in situ keratomileusis (LASIK) for myopia. SETTING Department of Ophthalmology, Goethe University, Frankfurt am Main, Germany. METHODS One month postoperatively, wavefront sensing was performed and overall subjective quality of vision assessed under 3 lighting conditions (photopic, high mesopic,...

متن کامل

Refractive error sensing from wavefront slopes.

The problem of measuring the objective refractive error with an aberrometer has shown to be more elusive than expected. Here, the formalism of differential geometry is applied to develop a theoretical framework of refractive error sensing. At each point of the pupil, the local refractive error is given by the wavefront curvature, which is a 2 × 2 symmetric matrix, whose elements are directly re...