Liquid chromatographic analysis of vitamin K1 in milk-based infant formula with matrix solid-phase dispersion.
نویسندگان
چکیده
A liquid chromatographic method for vitamin K1 in milk-based infant formula is described. The vitamins are extracted from infant formula by matrix solid-phase dispersion and quantitated by reversed-phase chromatography with fluorescence detection. Vitamin K1 is converted to the fluorescent hydroquinone with a postcolumn zinc reductive reactor. The limit of detection is 12 pg, and the limit of quantitation is 38 pg on-column. Linear responses were obtained in the range 0.55-22.1 ng/ml (r2 = 0.9998). Recoveries of vitamin K1 from an analyte-fortified blank material for milk-based infant formula averaged 91.7% (n = 25). The method provides a rapid, specific, and easily controlled assay for vitamin K1 in fortified infant formula.
منابع مشابه
Determination of vitamin K1 in medical foods by liquid chromatography with postcolumn reduction and fluorometric detection.
A liquid chromatographic (LC) method is described for the determination of vitamin K1 in medical foods. The sample is enzymatically digested with lipase and alpha-amylase and extracted with 1% sodium bicarbonate solution-isopropanol (1 + 1). After C18 solid-phase extraction, vitamin K1 is separated by nonaqueous reversed-phase LC, converted to the hydroquinone by postcolumn zinc reduction, and ...
متن کاملDetermination of vitamin K1 isomers in foods by liquid chromatography with C30 bonded-phase column.
Vitamin K1 was determined in a variety of foods by using reversed-phase liquid chromatography with a C30 column followed by post-column reduction to the fluorescent hydroquinone derivatives. Lipids were removed by lipase digestion, followed by single extraction into hydrocarbon, and the protocol was extended to selected natural and processed foods. Biologically active trans- and inactive ci-vit...
متن کاملAccelerated solvent extraction of vitamin K1 in medical foods in conjunction with matrix solid-phase dispersion.
An extraction technique is described for vitamin K1 in medical foods, using accelerated solvent extraction (ASE) in conjunction with matrix solid-phase dispersion (MSPD). The medical food sample is treated as it would be with MSPD extraction, followed by ASE for a hands-free automated extraction. The vitamin K1 in the ASE extract is then quantitated by reversed-phase liquid chromatography with ...
متن کاملUltrasonic-Assisted Matrix Solid-Phase Dispersion and High-Performance Liquid Chromatography as an Improved Methodology for Determination of Oleuropein from Olive Leaves
In this study, ultrasonic-assisted matrix solid-phase dispersion (UA-MSPD) as a new sample preparation method for natural product analysis was developed. Influential parameters of the UA-MSPD method was optimized using oleuropein content of olive leaves as a model analyte. Main parameters of the proposed technique such as ultrasonic time, amplitude and pulse, sorbent material, the ratio of samp...
متن کاملDetermination of Malathion and α-Endosulfan Residue in Khazar Rice Using Matrix Solid Phase Dispersion and HPLC
An extraction method based on matrix solid phase dispersion (MSPD) and high performance liquid chromatography with UV detection for quantification of two widely used pesticides (Malathion and α-Endosulfan) in Khazar rice from north of Iran were investigated. The ratio of solid phase (adsorbent) to sample, types of eluting solvent and its volume were optimized to achieve the highest recoveries f...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of AOAC International
دوره 82 5 شماره
صفحات -
تاریخ انتشار 1999