Removal of temporary pacemaker after cardiac surgery in infants: A harmless procedure?
نویسندگان
چکیده
External pacemakers (PM) via temporary epicardial leads are routinely applied to infants and children during heart surgery, which usually, after an uneventful post surgical course, can be removed without complications. We report about two infants with complex congenital heart defects after cardiac surgery (arterial switch and Mustard operation for Transposition of the great arteries). Intraoperative these patients received temporary epicardial PM wires. Thirteen and 18 days post surgery, respectively, the PM wires were removed under electrocardiogram (ECG) monitoring. The patients showed acute ECG changes in terms of significant ST elevation during and after removing their pacing wires. Clinically, patients were stable and subsequent echocardiographic examination showed no evidence of myocardial dysfunction or pericardial effusion. In the course of time, patients showed no signs of arrhythmia or abnormal ECG changes. The decision to place temporary pacing wires during the cardiac surgery in patients with congenital heart defects should be considered carefully and their removal should occur under ECG monitoring as soon as the situation of the patient allows. It should be taken into consideration that a complication like this case may be related to delayed removal of temporary PM’s leads.
منابع مشابه
بلوک کامل قلبی مادرزادی، معرفی یک مورد و مرور مقالات مشابه
Abstract: Background and Aim: Since electrocardiography (ECG) is essential for the diagnosis of pediatric asymptomatic Complete Heart Block (CHB) and it is not usually done in the preoperative evaluation of asymptomatic children, physicians might confront with asymptomatic cases of CHB at anesthesia induction. Case Report: In this study, we introduced a 31-month-old boy who faced CHB after anes...
متن کاملIs there a correlation between late re-exploration after cardiac surgery and removal of epicardial pacemaker wires?
BACKGROUND Re-exploration for bleeding accounts for increased morbidity and mortality after major cardiac operations. The use of temporary epicardial pacemaker wires is a common procedure at many departments. The removal of these wires postoperatively can potentially lead to a serious bleeding necessitating intervention. METHODS From Jan 2011 till Dec 2015 a total of 4244 major cardiac proced...
متن کاملClinical and mechanical factors associated with the removal of temporary epicardial pacemaker wires after cardiac surgery
BACKGROUND Temporary pacemaker wires are placed in the majority of patients after cardiac surgery. There is no information on mechanical factors related to wire removal. METHODS Clinical information related to temporary wire use and removal was prospectively collected from a large cardiac surgical unit over one year. Measurements of maximal tension that nurses and doctors would apply to remov...
متن کاملThe Improvement of the Atrial Flutter Rhythm upon the Removal of the Infected Permanent Pacemaker Lead
Pacemaker infection has multiple risk factors. Its presentation is most often similar to infected endocarditis and the diagnosis is made through studying blood cultures. Transesophageal echocardiography can confirm the diagnosis. The most common microorganisms are staphylococcus speciesis. As a matter of fact, complete pacemaker removal appears to be the only definite treatment. We presented a ...
متن کاملFaulty design resulting in temporary pacemaker failure.
A 77-year-old man became asystolic 3 days after aortic valve replacement and coronary artery bypass surgery. A dual-chamber temporary pacemaker generator was turned on but failed to discharge; instead, an obscure error message appeared on the liquid crystal display of the pacemaker. The intensive-care nurses and physicians were unable to activate the pacemaker. We describe the pacemaker design ...