Turbulent flow as a cause for underestimating coronary flow reserve measured by Doppler guide wire
نویسندگان
چکیده
BACKGROUND Doppler-tipped coronary guide-wires (FW) are well-established tools in interventional cardiology to quantitatively analyze coronary blood flow. Doppler wires are used to measure the coronary flow velocity reserve (CFVR). The CFVR remains reduced in some patients despite anatomically successful coronary angioplasty. It was the aim of our study to test the influence of changes in flow profile on the validity of intra-coronary Doppler flow velocity measurements in vitro. It is still unclear whether turbulent flow in coronary arteries is of importance for physiologic studies in vivo. METHODS We perfused glass pipes of defined inner diameters (1.5-5.5 mm) with heparinized blood in a pulsatile flow model. Laminar and turbulent flow profiles were achieved by varying the flow velocity. The average peak velocity (APV) was recorded using 0.014 inch FW. Flow velocity measurements were also performed in 75 patients during coronary angiography. Coronary hyperemia was induced by intra-coronary injection of adenosine. The APV maximum was taken for further analysis. The mean luminal diameter of the coronary artery at the region of flow velocity measurement was calculated by quantitative angiography in two orthogonal planes. RESULTS In vitro, the measured APV multiplied with the luminal area revealed a significant correlation to the given perfusion volumes in all diameters under laminar flow conditions (r2 > 0.85). Above a critical Reynolds number of 500--indicating turbulent flow--the volume calculation derived by FW velocity measurement underestimated the actual rate of perfusion by up to 22.5 % (13 +/- 4.6 %). In vivo, the hyperemic APV was measured irrespectively of the inherent deviation towards lower velocities. In 15 of 75 patients (20%) the maximum APV exceeded the velocity of the critical Reynolds number determined by the in vitro experiments. CONCLUSION Doppler guide wires are a valid tool for exact measurement of coronary flow velocity below a critical Reynolds number of 500. Reaching a coronary flow velocity above the velocity of the critical Reynolds number may result in an underestimation of the CFVR caused by turbulent flow. This underestimation of the flow velocity may reach up to 22.5 % compared to the actual volumetric flow. Cardiologists should consider this phenomena in at least 20 % of patients when measuring CFVR for clinical decision making.
منابع مشابه
Non-invasive measurement of coronary flow reserve in children with Kawasaki disease.
OBJECTIVE To investigate whether transthoracic Doppler echocardiography (TTE) can reliably measure the coronary flow reserve in the left anterior descending coronary artery in children with Kawasaki disease. DESIGN Coronary flow velocity in the distal left anterior descending coronary artery was measured by TTE and was compared with that obtained by intracoronary Doppler guide wire. The ratio...
متن کاملCoronary thermodilution to assess flow reserve: validation in humans.
BACKGROUND Guide wire-based simultaneous measurement of fractional flow reserve (FFR) and coronary flow reserve (CFR) is important to understand microvascular disease of the heart. The aim of this study was to investigate the feasibility of simultaneous measurement of FFR and CFR by one pressure-temperature sensor-tipped guide wire with the use of coronary thermodilution and to compare CFR by t...
متن کاملNew applications of intracardiac echocardiography: assessment of coronary blood flow by colour and pulsed Doppler imaging in dogs.
OBJECTIVE To explore the application of a new 10 French intracardiac echocardiography (ICE) catheter with phased array and Doppler capable transducer for the assessment of epicardial and intramyocardial coronary blood flow. METHODS The coronary arteries were detected by cross sectional imaging in seven closed chest dogs, and coronary blood flow visualised by colour Doppler. Blood flow velocit...
متن کاملCORONARY BLOOD FLOW Noninvasive Assessment of Coronary Flow Velocity and Coronary Flow Velocity Reserve in the Left Anterior Descending Coronary Artery by Doppler Echocardiography Comparison With Invasive Technique
Objectives. The purpose of this study was to evaluate whether transthoracic Doppler echocardiography (TTDE) can reliably measure coronary flow velocity (CFV) and coronary flow velocity reserve (CFVR) in the left anterior descending coronary artery (LAD) in the clinical setting. Background. Coronary flow velocity measurement has provided useful clinical and physiologic information. Advancement i...
متن کاملEvaluation of coronary flow velocity dynamics and flow reserve in patients with Kawasaki disease by means of a Doppler guide wire.
OBJECTIVES To assess the pathophysiologic effects of the coronary sequelae of Kawasaki disease on coronary hemodynamic variables, we regionally evaluated the flow velocity dynamics and flow reserve in coronary vessels with lesions using an intracoronary Doppler flow guide wire. BACKGROUND The pathophysiologic effects of the coronary sequelae of Kawasaki disease on coronary hemodynamic variabl...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Cardiovascular Ultrasound
دوره 4 شماره
صفحات -
تاریخ انتشار 2006