Isotopic analogues as internal standards for quantitative analyses of drugs and metabolites by GC-MS--nonlinear calibration approaches.
نویسندگان
چکیده
In order to achieve accurate quantitation of drugs and metabolites (analytes) in complex matrices, 2H- (and less commonly 13C-) labeled analogues of the analytes are now routinely adapted as the internal standards (IS) using linear calibration models to fit data generated by selected ion monitoring gas chromatography-mass spectrometry (GC-MS) protocols. In this study, the effects of cross-contribution (contribution of the IS to the intensity of the ion designated for the analyte and vice versa) on the linearity of the calibration data are examined. Nonlinear approaches that may address this problem are also studied. Two ion pairs (one with least and one with significant cross-contribution) from each of the following analyte/IS pairs are used as the exemplar systems for this study: butalbital/13C4-butalbital, butalbital/2H5-butalbital, secobarbital/13C4-secobarbital, and secobarbital/2H5-secobarbital. Analyte/IS ion intensity ratios of a series of standard solutions are correlated with the analyte/IS concentration ratios using one-point, multiple-point (unweighted and weighted) linear, and hyperbolic functions. The one-point calibration approach produces excellent calibration results in treating data derived from ion pairs with no significant cross contribution. In cases where significant cross-contribution exists, results derived from the one-point approach show, as expected, significant deviations at both ends of the concentration range. With the cross-contribution phenomenon accounted for, the hyperbolic calibration model is clearly more effective in fitting calibration data at both the lower and higher analyte concentration ends, thus significantly lowering the detection limit and extending the calibration range to a higher level. However, the calibration range cannot be extended indefinitely. At the low concentration end, noise-to-signal ratio and the cross-contribution of the IS to the intensity of the ion designated for the analyte, however insignificant, will incrementally reduce the quality of the observed ion intensity and intensity ratio data. At the high concentration end, detection saturation and the cross-contribution of the analyte to the intensity of the ion designated for the IS, however insignificant, will incrementally decrease the "slope" of the calibration curve. Thus, acceptable sensitivity (increase in analyte/IS ion-pair intensity ratio per unit increase in analyte concentration) of the calibration curve will become the limiting factor.
منابع مشابه
Study of the retention behaviour of monofluorinated analogues of Polybrominated Diphenylethers (F-PBDEs) in gas chromatography
Introduction Polybrominated diphenyl ethers (PBDEs) are globally distributed in the environment. They have been used as flame retardants for over 2 decades [1]. PBDEs have been found to bioaccumulate and there is also a concern about the health effects of PBDE exposure due to their potential endocrine disrupting properties. PBDEs are structurally similar to polychlorinated biphenyls (PCBs) and ...
متن کاملReplacing immunoassays for mephedrone, ketamines and six amphetamine-type stimulants with flow injection analysis tandem mass spectrometry.
A screening procedure was developed for the simultaneous detection of mephedrone, six amphetamine-type stimulants (ATS), ketamine and its two metabolites with electrospray ionization flow injection analysis tandem mass spectrometry (FIA-MS-MS). Urine samples were fortified with deuterated analogues as internal standards, extracted with ethyl acetate and analyzed with FIA-MS-MS. The mass analyze...
متن کاملRelative Determination Approach to the Metabolites of Protoberberine Alkaloids in Rat Urine by Liquid Chromatography Tandem Mass Spectrometry for the Comparative Studies on Rhizome coptidis and Zuojinwan Preparation
The lack of authentic standards has limited the quantitative analysis of herbal drugs in biological samples. The present work demonstrated a practicable strategy for the assay of herbs and their metabolites independent of authentic standards. A liquid chromatography–electrospray ionization–mass spectrometry (LC–ESI–MS) method for the qualitative and quantitative determination of the metabolites...
متن کاملRelative Determination Approach to the Metabolites of Protoberberine Alkaloids in Rat Urine by Liquid Chromatography Tandem Mass Spectrometry for the Comparative Studies on Rhizome coptidis and Zuojinwan Preparation
The lack of authentic standards has limited the quantitative analysis of herbal drugs in biological samples. The present work demonstrated a practicable strategy for the assay of herbs and their metabolites independent of authentic standards. A liquid chromatography–electrospray ionization–mass spectrometry (LC–ESI–MS) method for the qualitative and quantitative determination of the metabolites...
متن کاملRapid diagnosis of drug intoxication using novel NAGINATA gas chromatography/mass spectrometry software.
In Japan, not only the classical stimulant, methamphetamine, but also a wide variety of illicit drugs and designer drugs are abused by juveniles. It is, however, difficult to screen these drugs in human urine due to the poor availability of high-quality standards. Therefore, it is important to develop a screening method that does not require the use of standard compounds. Furthermore, if we can...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of analytical toxicology
دوره 25 3 شماره
صفحات -
تاریخ انتشار 2001