Cell membrane electropermeabilization by symmetrical bipolar rectangular pulses. Part II. Reduced electrolytic contamination.

نویسندگان

  • T Kotnik
  • D Miklavcic
  • L M Mir
چکیده

The paper presents a comparative study of the contamination of a cell suspension by ions released from aluminum cuvettes (Al(3+)) and stainless steel electrodes (Fe(2+)/Fe(3+)) during cell membrane electropermeabilization by unipolar and by symmetrical bipolar rectangular electric pulses. A single pulse and a train of eight pulses were delivered to electrodes at a 2-mm distance, with 100-micros and 1-ms pulse durations, and amplitudes ranging from 0 to 400 V for unipolar, and from 0 to 280 V for bipolar pulses. We found that the released concentrations of Al(3+) and Fe(2+)/Fe(3+) were always more than one order of magnitude lower with bipolar pulses than with unipolar pulses of the same amplitude and duration. We then investigated the viability of DC-3F cells after 1 h of incubation in the medium containing different concentrations of Al(3+) or Fe(2+)/Fe(3+) within the range of measured released concentrations (up to 2.5 mM for both ions), thus separating the effects of electrolytic contamination from the effects of electropermeabilization itself. For Fe(2+)/Fe(3+), loss of cell viability became significant at concentrations above 1.5 mM, while for Al(3+), no effect on cell survival was detected within the investigated range. Still, reports on the biochemical effects of released Al(3+) also suggest that with aluminum cuvettes, electrolytic contamination can be detrimental. Our study shows that electrolytic contamination and its detrimental effects can be largely reduced with no loss in efficiency of electropermeabilization, if bipolar rectangular pulses of the same amplitude and duration are used instead of the commonly applied unipolar pulses.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cell membrane electropermeabilization by symmetrical bipolar rectangular pulses. Part I. Increased efficiency of permeabilization.

The paper presents a comparative study of electropermeabilization of cells in suspension by unipolar and symmetrical bipolar rectangular electric pulses. While the parameters of electropermeabilization by unipolar pulses have been investigated extensively both in cell suspensions and in tissues, studies using bipolar pulses have been rare, partly due to the lack of commercially available bipola...

متن کامل

Cell membrane electropermeabilization with arbitrary pulse waveforms.

xposure of a biological cell to an electric field can produce a variety of responses [1]-[6]. If the field strength exceeds a certain threshold value, this leads to a large transient increase in membrane conductivity and permeability for ions and molecules (electropermeabilization, often also named electroporation) or to fusion of adjacent cells (electrofusion) [5], [6]. Nowadays, these phenome...

متن کامل

Role of pulse shape in cell membrane electropermeabilization.

The role of the amplitude, number, and duration of unipolar rectangular electric pulses in cell membrane electropermeabilization in vitro has been the subject of several studies. With respect to unipolar rectangular pulses, an improved efficiency has been reported for several modifications of the pulse shape: separate bipolar pulses, continuous bipolar waveforms, and sine-modulated pulses. In t...

متن کامل

The effect of resting transmembrane voltage on cell electropermeabilization: a numerical analysis.

The transmembrane voltage induced due to applied electric field superimposes to the resting transmembrane voltage of the cell. On the part of the cell membrane, where the transmembrane voltage exceeds the threshold transmembrane voltage, changes in the membrane occur, leading to increase in membrane permeability known as electropermeabilization. This part of the cell membrane represents the per...

متن کامل

The temperature effect during pulse application on cell membrane fluidity and permeabilization.

Cell membrane permeabilization is caused by the application of high intensity electric pulses of short duration. The extent of cell membrane permeabilization depends on electric pulse parameters, characteristics of the electropermeabilization media and properties of cells exposed to electric pulses. In the present study, the temperature effect during pulse application on cell membrane fluidity ...

متن کامل

ذخیره در منابع من