Case Report : Severe allergic reaction to Physiomesh after laparoscopic ventral hernia repair
نویسنده
چکیده
Due to a relative high rate of recurrence compared with other meshes for laparoscopic ventral hernia repair, Physiomesh® was recalled in 2016. This case report describes one of two reported cases of allergic reaction after insertion of Physiomesh®. The patient was a 50-year-old male who had a laparoscopic operation for ventral hernia with insertion of Physiomesh® as an intraperitoneal onlay procedure. Two months later, the patient was admitted with intense epigastric pain, and CT scan showed signs of ileus. Emergency surgery was performed revealing severe allergic signs in the abdomen and retroperitoneum. The mesh was removed. The postoperative course was complicated; the patient had multiple admissions with incomplete ileus, as well as recurrence of the ventral hernia. An open sublay hernia repair using a monofilament polyester mesh was subsequently performed with good effect. This case report illustrates a rare complication with mesh insertion. This adverse event adds to the risk of complications following implantation of mesh to reinforce a hernia repair. The allergic reaction was not suspected until during operation. Therefore, this report also illustrates the importance of surgeons’ clinical assessment and ability to take relevant action, which in this case consisted of mesh removal and retrieving tissue samples for histology. Laura Quitzau Mortensen ( ) Corresponding author: [email protected] Competing interests: LQM, TB and TPH have nothing to disclose. JR reports grants from Johnson & Johnson, grants and personal fees from Bard, personal fees from Merck, outside the submitted work. Mortensen LQ, Bisgaard T, Hansen TP and Rosenberg J. How to cite this article: Case Report: Severe allergic reaction to Physiomesh 2017, :685 (doi: after laparoscopic ventral hernia repair [version 1; referees: 1 approved with reservations] F1000Research 6 ) 10.12688/f1000research.10798.1 © 2017 Mortensen LQ . This is an open access article distributed under the terms of the , Copyright: et al Creative Commons Attribution Licence which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. The author(s) declared that no grants were involved in supporting this work. Grant information: 17 May 2017, :685 (doi: ) First published: 6 10.12688/f1000research.10798.1 ®
منابع مشابه
Ventralight ST and SorbaFix Versus Physiomesh and Securestrap in a Porcine Model
BACKGROUND AND OBJECTIVES The objective of this study was to compare mesh contracture, adhesion characteristics, tissue ingrowth, and histologic response of Ventralight ST/SorbaFix (C.R. Bard/Davol, Warwick, RI, USA) with Physiomesh/Securestrap (Ethicon, Somerville, NJ, USA) in a porcine model of laparoscopic ventral hernia repair. METHODS Standard laparoscopic technique was used to bilateral...
متن کاملVentral Hernia After Hand-Assisted Laparoscopic Nephrectomy
Introduction: The incidence of incisional hernias after hand-assisted laparoscopic surgery (HALS) ranges from 3 to 10%. Robotic-assisted ventral hernia repair is technically feasible and gaining popularity as an acceptable alternative to open repair. Case Report: We report a case of a robot-assisted repair for an incisional hernia from a hand-assist port site in a 50-year-old man after a hand-a...
متن کاملPreclinical evaluation of the effect of the combined use of the Ethicon Securestrap® Open Absorbable Strap Fixation Device and Ethicon Physiomesh™ Open Flexible Composite Mesh Device on surgeon stress during ventral hernia repair
Aim To evaluate whether performing ventral hernia repairs using the Ethicon Physiomesh™ Open Flexible Composite Mesh Device in conjunction with the Ethicon Securestrap® Open Absorbable Strap Fixation Device reduces surgical time and surgeon stress levels, compared with traditional surgical repair methods. Methods To repair a simulated ventral incisional hernia, two surgeries were performed by...
متن کاملSingle incision laparoscopic primary and incisional ventral hernia repair as the standard of care in the ambulatory setting; Does less equal better outcomes; Case series and literature review
INTRODUCTION The consensus about whether the single port approach is advantageous remains controversial. As the ambulatory service becomes the standard of care, techniques are in evolution to augment the patient experience in this setting. This forms the basis for evaluating SILS (Single Incision Laparoscopic Surgery) prosthetic ventral hernia repair in the ambulatory setting. We report a SILS ...
متن کاملLaparoscopic totally extra-peritoneal hernia repair for bilateral Spigelian hernias and coincident inguinal hernia: A case report
INTRODUCTION Spigelian hernia (SH) is a rare ventral hernia occurring near the lateral border of the rectus muscle. The treatment remains controversial and depends on institutional expertise. Although laparoscopic surgery is a good adaptation for the repair of ventral hernias, only a few cases have been reported in the literature. Here, we report a case of totally extra-peritoneal (TEP) repair ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید