Blood glucose measurement with Dextrostix and new reflectance meter.

نویسندگان

  • B Schersten
  • C Kuhl
  • A Hollender
  • R Ekman
چکیده

A new instrument, Eyetone, has been produced for use with a Dextrostix reagent strip for estimating blood sugar levels. It differs from the Dextrostix Reflectance Meter in having only one meter scale, a two-point calibration, and a range of measurement limited to 10-400 mg/100 ml. Results with the manufacturers' original calibration were unsatisfactory, but when recalibrated the performance of the instrument gave a regression equation line close to the ideal. The three Eyetone instruments tested were comparable in their accuracy and functional stability. Packed cell volumes in the blood samples in the range of 30-50% had a negligible effect on the results. The Dextrostix-Eyetone method represents a quick and reliable alternative to conventional laboratory methods for blood sugar estimation. It is especially useful for patients outside hospital.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The "eyetone" blood glucose reflectance colorimeter evaluated for in vitro and in vivo accuracy and clinical efficacy.

We evaluated the performance of a blood glucose reflectance colorimeter ("Eyetone," Ames Co.) for accuracy and precision with use of "Dextrostix" (Ames Co.) glucose oxidase reagent strips for blood samples with known and unknown concentrations of glucose covering the usual range of neonatal blood glucose (200-800 mg/L). The meter was calibrated and tested by research nurses and one clinical che...

متن کامل

Rapid detection of neonatal hypoglycaemia

The use of Dextrostix Reflectance Meter (DRM)* to measure blood glucose has been reported recently. The method has proved to be simnple, rapid, and accurate, and to correlate well with various reference methods (Mazzaferri et al., 1970; Jarret, Keen, and Hardwick, 1970; Schersten, 1971; Deckert and Futtrup, 1971). The handiness of the DRM seemed to make it an excellent tool in the diagnosis of ...

متن کامل

Rapid detection of neonatal hypoglycaemia

The use of Dextrostix Reflectance Meter (DRM)* to measure blood glucose has been reported recently. The method has proved to be simnple, rapid, and accurate, and to correlate well with various reference methods (Mazzaferri et al., 1970; Jarret, Keen, and Hardwick, 1970; Schersten, 1971; Deckert and Futtrup, 1971). The handiness of the DRM seemed to make it an excellent tool in the diagnosis of ...

متن کامل

Diagnosis and treatment of hypoglycaemia in the newborn.

The importance of hypoglycaemia, defined as a true blood glucose below 20 mg./100 ml., in the newborn infant is now well recognized. It is sometimes found in the idiopathic respiratory distress syndrome (RDS), in infants of diabetic mothers, and in neonatal cold injury, and it may also occur in association with anoxia, cerebral haemorrhage, or infection (Neligan, 1965). The majority of symptoma...

متن کامل

Performance and storage of reagent strips for measuring blood glucose.

Performance and storage of reagent strips for measuring blood glucose Use of reagent strips to monitor blood glucose concentrations in diabetic patients, with or without a glucose meter, is gaining in popularity. Favourable performance of the recently introduced Boehringer BM Test Glycemie 20-800 strips has been reported.'-4 We compared Boehringer strips and Dextrostix (Ames) with laboratory me...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • British medical journal

دوره 3 5927  شماره 

صفحات  -

تاریخ انتشار 1974