Duration of Systole and Diastole for Hydrodynamic Testing of Prosthetic Heart Valves: Comparison Between ISO 5840 Standards and in vivo Studies
نویسندگان
چکیده
OBJECTIVE To complement the ISO 5840 standards concerning the duration of left ventricular systole and diastole as a function of changes in heart rates according to in vivo studies from the physiologic literature review. METHODS The systolic and diastolic durations from three in vivo studies were compared with the durations of systole proposed by the ISO 5840:2010 and ISO 5840-2:2015 for hydrodynamic performance assessment of prosthetic heart valves. RESULTS Based on the in vivo studies analyzed, the systolic durations proposed by the ISO 5840 standard seemed consistent for 45 and 120 beats per minute (bpm), and showed diverse results for the 70 bpm condition. CONCLUSION Information on the realistic validation of the operation of left ventricular models for different heart rates were obtained.
منابع مشابه
Update of the European standards for inactive surgical implants in the area of heart valve prostheses.
OBJECTIVE The approval of a heart valve for the European market takes place in accordance with European and international standards. A new version of the EN Standards was published in June 2006, which responded to different technical innovations in the area of heart valve technology. This work outlines the differences between the new EN ISO 5840 (2005) and the old EN 12006-1 (1999). METHODS W...
متن کاملExperimental Validation of a Cardiac Simulator for in vitro Evaluation of Prosthetic Heart Valves
OBJECTIVE This work describes the experimental validation of a cardiac simulator for three heart rates (60, 80 and 100 beats per minute), under physiological conditions, as a suitable environment for prosthetic heart valves testing in the mitral or aortic position. METHODS In the experiment, an aortic bileaflet mechanical valve and a mitral bioprosthesis were employed in the left ventricular ...
متن کاملFluid dynamic characterization of a polymeric heart valve prototype (Poli-Valve) tested under continuous and pulsatile flow conditions.
PURPOSE Only mechanical and biological heart valve prostheses are currently commercially available. The former show longer durability but require anticoagulant therapy; the latter display better fluid dynamic behavior but do not have adequate durability. New Polymeric Heart Valves (PHVs) could potentially combine the hemodynamic properties of biological valves with the durability of mechanical ...
متن کاملNew polyurethane prostheses for substitution of cardiac valve disease and remodeling of the right ventricle in congenital heart malformations
Methods Based on a computed tomography angiography of the aorta, we made a delrin ring, keeping the anatomical characteristics of the aortic annulus. A matrix one following we made from stainless steel with the shape of the three cusp aortic valve, followed by preparation of the injection of liquid polyurethane segmented (SPU), using a esterolitografia technique. In vitro tests: The materials u...
متن کاملPregnancy Outcome with Intracytoplasmic Sperm Injection Method in a Woman with Prosthetic Heart Valves
There is an increased risk of thromboembolism, anticoagulant-related hemorrhage, fetal-wastage and congestive cardiac failure in pregnant women with mechanical heart valves. In order to have a good outcome, the care of such patients must necessarily be multidisciplinary and in a well- equipped centre with adequate support services .One such patient who had mechanical mitral and aortic valves re...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 31 شماره
صفحات -
تاریخ انتشار 2016