Assessment of Regional Myocardial and Renal Blood Flow With CoppermPTSM and Positron Emission Tomography

نویسندگان

  • Marc E. Shelton
  • Michael J. Welch
چکیده

We recently demonstrated in isolated, perfused hearts that radiolabeled pyruvaldehyde bis(N4-methylthiosemicarbazonato)copper(II) (Cu-PTSM) is well extracted throughout a range of conditions including ischemia, hypoxia, and hyperemia. Once extracted, binding of radioactivity by the isolated heart was essentially irreversible, giving this tracer microspherelike qualities. Because Cu-PTSM can be readily prepared with the generator-produced positronemitting copper 62 and other gammaor positron-emitting copper radionuclides, we evaluated its usefulness for measuring regional myocardial and renal blood flow in vivo in intact dogs at rest, after ischemia, or after coronary hyperemia was induced by intravenous administration of dipyridamole. After intravenous administration of radiolabeled Cu-PTSM, the tracer cleared rapidly from the blood. Myocardial uptake of single photon-emitting 67Cu-labeled Cu-PTSM

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of regional myocardial and renal blood flow with copper-PTSM and positron emission tomography.

We recently demonstrated in isolated, perfused hearts that radiolabeled pyruvaldehyde bis(N4-methylthiosemicarbazonato)copper(II) (Cu-PTSM) is well extracted throughout a range of conditions including ischemia, hypoxia, and hyperemia. Once extracted, binding of radioactivity by the isolated heart was essentially irreversible, giving this tracer microspherelike qualities. Because Cu-PTSM can be ...

متن کامل

Positron Emission Tomography-Determined Hyperemic Flow, Myocardial Flow Reserve, and Flow Gradient—Quo Vadis?

Positron emission tomography/computed tomography (PET/CT) applied with positron-emitting flow tracers such as 13N-ammonia and 82Rubidium enables the quantification of both myocardial perfusion and myocardial blood flow (MBF) in milliliters per gram per minute for coronary artery disease (CAD) detection and characterization. The detection of a regional myocardial perfusion defect during vasomoto...

متن کامل

Quantification of regional myocardial perfusion with generator-produced 62Cu-PTSM and positron emission tomography.

BACKGROUND Noninvasive assessment of regional myocardial perfusion at rest and after stress is important for the objective evaluation of the effects of coronary artery disease and its response to therapy. Centers that do not have cyclotrons rely on generator-produced radioisotopes for assessment of regional myocardial perfusion with positron emission tomography (PET). The aim of the present stu...

متن کامل

Quantification of Regional Myocardial Blood Flow by Microspheres

Background. Both ['3N ammonia and ['5Olwater have been used to quantify myocardial blood flow with positron emission tomography using appropriate tracer kinetic models. A direct comparison of the two tracers with radioactive microspheres has not been performed in the same experimental preparation. Methods and Results. The two tracers have been tested for myocardial blood flow quantification in ...

متن کامل

Integration of Quantitative Positron Emission Tomography Absolute Myocardial Blood Flow Measurements in the Clinical Management of Coronary Artery Disease.

In the >40 years since planar myocardial imaging with(43)K-potassium was introduced into clinical research and management of patients with coronary artery disease (CAD), diagnosis and treatment have undergone profound scientific and technological changes. One such innovation is the current state-of-the-art hardware and software for positron emission tomography myocardial perfusion imaging, whic...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005