Effects of shock polarity reversal on defibrillation threshold in an implantable cardioverter-defibrillator.

نویسندگان

  • Agnieszka Zienciuk
  • Andrzej Lubiński
  • Tomasz Królak
  • Ewa Lewicka-Nowak
  • Maciej Kempa
  • Anna Pazdyga
  • Grzegorz Raczak
چکیده

BACKGROUND An increased defibrillation threshold (DFT) may limit the efficacy of an implantable cardioverter-defibrillator (ICD) in termination of life-threatening ventricular arrhythmias. A search for methods of decreasing DFT has been ongoing since the introduction of ICD into clinical practice. AIM To assess the effects of various shock polarities on DFT. METHODS The study group consisted of 19 patients (8 females and 11 males, mean age 52+/-17 years) who received devices (Biotronik, Germany) with a single-coil defibrillation lead. In all patients the value of DFT was assessed using a normal shock polarity as well as using a reversed polarity shock, starting from the energy lower than that measured during normal DFT testing. The impedance of the defibrillation system using two different polarities was also measured. The effects of demographic and clinical parameters on defibrillation parameters were also examined. RESULTS When using normal shock polarity, the mean DFT value was 12+/-5 J (range 3.1-20 J) and impedance was 64+/-12 Omega. When shock polarity was reversed, the mean DFT value was 9.2+/-5.0 J (range 2-20 J) and impedance was 67+/-11 Omega. In 11 (58%) patients the polarity change caused a marked (by 37%) decrease in the mean DFT value - from 11.5+/-5.1 J to 7.2+/-3.8 J. In 5 patients DFT reduction was > or = 5 J. There was no relationship between demographic or clinical parameters and defibrillation efficacy using the two tested shock polarities. CONCLUSIONS The reversal of shock polarity reduces DFT in more than half of patients. In patients with a high DFT the use of reversed polarity of defibrillating impulse may reduce DFT, which widens the safety margin and makes implantation of additional leads unnecessary. Because clinical parameters have no value in predicting the effects of polarity changes on DFT, the efficacy of reversed polarity shock has to be assessed individually in each patient.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Basic Mechanism of Defibrillation Failure

Delivery of a strong electric shock to the heart remains the only effective therapy against ventricular fibrillation. Despite significant improvements in implantable cardioverter defibrillator (ICD) therapy, the fundamental mechanisms of defibrillation remain poorly understood. We have recently demonstrated that a monophasic defibrillation shock produces a highly nonuniform epicardial polarizat...

متن کامل

Elevated Defibrillation Threshold: Are Defibrillation Vectors Important?

The evaluation of the defibrillation threshold (DFT) is common after the implantation of implantable cardioverter defibrillator (ICD) devices. The goal of this standard of care is to achieve successful defibrillation of ventricular fibrillation. In patients with elevated defibrillation thresholds, alternative techniques are required to correct the situation. We describe a case in which an uncom...

متن کامل

Inductionless or limited shock testing is possible in most patients with implantable cardioverter- defibrillators/cardiac resynchronization therapy defibrillators: results of the multicenter ASSURE Study (Arrhythmia Single Shock Defibrillation Threshold Testing Versus Upper Limit of Vulnerability: Risk Reduction Evaluation With Implantable Cardioverter-Defibrillator Implantations).

BACKGROUND Implantable cardioverter-defibrillators and cardiac resynchronization therapy defibrillators have relied on multiple ventricular fibrillation (VF) induction/defibrillation tests at implantation to ensure that the device can reliably sense, detect, and convert VF. The ASSURE Study (Arrhythmia Single Shock Defibrillation Threshold Testing Versus Upper Limit of Vulnerability: Risk Reduc...

متن کامل

Intraoperative Defibrillation Testing of Subcutaneous Implantable Cardioverter‐Defibrillator Systems—A Simple Issue?

BACKGROUND The results of the recently published randomized SIMPLE trial question the role of routine intraoperative defibrillation testing. However, testing is still recommended during implantation of the entirely subcutaneous implantable cardioverter-defibrillator (S-ICD) system. To address the question of whether defibrillation testing in S-ICD systems is still necessary, we analyzed the dat...

متن کامل

Decreased Defibrillation Threshold and Minimized Myocardial Damage With Left Axilla Implantable Cardioverter Defibrillator Implantation.

BACKGROUND To reduce myocardial damage caused by implantable cardioverter defibrillator (ICD) shock, the left axilla was studied as an alternative pulse generator implantation site, and compared with the traditional implantation site, the left anterior chest. METHODSANDRESULTS Computer simulation was used to study the defibrillation conduction pattern and estimate the simulated defibrillation...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Kardiologia polska

دوره 65 5  شماره 

صفحات  -

تاریخ انتشار 2007