Spontaneous Absorption of Cerebral Air Embolus Developed Accidentally during an Intra-arterial Procedure

نویسنده

  • Tae Ki Yang
چکیده

Cerebral arterial air embolism (CAAE), although infrequent, is a complication that can occur at any time during an invasive medical procedure. We experienced two cases of CAAE during cerebral angiography accidentally. The author reports the two cases of CAAE wherein air emboli dissolved spontaneously and immediately under normal atmospheric pressure, not under therapeutic hyperbaric environment. One of the cases shows entire dissolution of the air embolus on the moving image. This report shows that arterial air embolus can be absorbed spontaneously, and air embolus size is one of the factors that influence air embolus dissolution besides hyperbaric oxygen condition.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Acute stroke from air embolism to the middle cerebral artery following upper gastrointestinal endoscopy

Acute stroke from cerebral-artery air embolism is a very rare occurrence during esophagogastroduodenoscopy (EGD). Computed tomography is a quick and reliable method of detecting cerebral air embolism if performed within an appropriate timeframe. We found 20 reported cases of air embolism with EGD in the literature; only seven of those resulted in cerebral air embolus. We report an eighth such c...

متن کامل

Heparin and air filters reduce embolic events caused by intra-arterial cerebral angiography: a prospective, randomized trial.

BACKGROUND Intra-arterial cerebral angiography is associated with a low risk for neurological complications, but clinically silent ischemic events after angiography have been seen in a substantial number of patients. METHODS AND RESULTS In a prospective study, diffusion-weighted magnetic resonance imaging (DW-MRI) before and after intra-arterial cerebral angiography and transcranial Doppler s...

متن کامل

Recanalization by mechanical embolus disruption during intra-arterial thrombolysis in the carotid territory.

BACKGROUND AND PURPOSE Mechanical disruption of a clot with a microcatheter and a guidewire has not been detailed in conjunction with intra-arterial thrombolysis in patients with acute ischemic stroke. The purpose of this study was to evaluate the efficacy of mechanical disruption of an embolus in the carotid artery distribution. METHODS We analyzed clinical and radiologic findings and functi...

متن کامل

Experimental air embolism of the brain: an analysis of the technique in the rat.

Air embolization of the brain produces cerebral ischemia that can be focal and reversible. The method has previously been hampered by (1) lack of selective arterial injection of the embolus, (2) disruption of local hemodynamic relationships by ligation of major arterial channels, (3) excessive volume of the air embolus, and (4) uncontrolled bubble size. To minimize these factors, a technique wa...

متن کامل

Symptomatic cerebral air embolism during neuro-angiographic procedures: incidence and problem avoidance.

BACKGROUND While clinically symptomatic cerebral air embolism secondary to neuro-angiographic procedures is rare, the incidence in a large series of procedures is unknown. Understanding this complication's frequency and etiology is critical if systems are to be instituted to reduce its incidence. METHODS We prospectively reviewed 4,568 consecutive neuro-angiographic procedures performed betwe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 18  شماره 

صفحات  -