The stratus automated immunofluorometric assay system: a modification for measuring urinary human choriogonadotropin.

نویسندگان

  • R J van den Berg
  • M F Segers
  • C M Thomas
چکیده

The fluorometric enzyme immunoassays that can be run on the automated Stratus analyzer (American Dade, Miami, FL) are based on monoclonal antibodies coated to glass-fiber paper tabs. The available assays are specifically designed for quantification of analytes in plasma and serum, but not in urine. For example, eight urine samples with hCG concentrations <2.5 mt.units/L according to the Tandem-E immunoenzymometric assay for urinary intact hCG (Hybritech Europe SA, Liege, Belgium) had apparent hCG concentrations ranging between 9.3 and 16 mt. unitsfL when measured with the Stratus. To further investigate this observation, we processed 35 urine samples for intact hCG with the Stratus (y) and compared these with results with the Tandem-E (x). Regression analysis between the two “sandwich”-type assays revealed the following equation: y = 1.45x + 9.20 mt.unita/L, S = 7.0, = 55 mt. unitsiL, r = 0.987 (Figure 1A). Apart from possible differences in specificities between the two hCG assays compared, we suspected a matrix effect with the Stratus. To test this, we treated the glass-fiber paper tabs of the hCG assay with 50 L of Stratus sample diluent (i.e., processed human serum included in the kit), then assayed 38 urine samples for hCG content with these pretreated tabs on the Stratus [Stratus(+)]. Regression analysis of these results yielded the following: Stratus(+)

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Modification of the choriogonadotropin beta-subunit radioimmunoassay for determination of urinary choriogonadotropin.

The choriogonadotropin beta-subunit radioimminoassay has been used extensively to measure human choriogonadotropin in the sera of pregnant women and individuals with trophoblastic and nontrophoblastic tumors. Unmodified, this method cannot be used to measure choriogonadotropin in urine because of interfering substances. We circumvented the non-parallelism between the standards and serial diluti...

متن کامل

Time-resolved immunofluorometric assay and specimen storage conditions for measuring urinary gonadotropins.

We optimized storage conditions and validated a sensitive immunofluorometric assay (IFMA) for urinary gonadotropins. Assay linearity and parallelism for luteinizing hormone (LH) and follicle-stimulating hormone (FSH) was observed to 0.04 IU/L. Urinary LH and FSH were unaffected by changes of osmolarity from 0.5 to 3.0 mOsm/kg, and from pH 4.5 to 10.5. Serum and urine measurements of the hormone...

متن کامل

Choriogonadotropin and its beta subunit separated by hydrophobic-interaction chromatography and quantified in serum during pregnancy by time-resolved immunofluorometric assays.

Concentrations of human choriogonadotropin (hCG) and its free beta subunit (beta hCG) were measured in serum by highly sensitive and specific time-resolved immunofluorometric assays (IFMAS). The results were confirmed by completely separating beta hCG and hCG by a novel method based on hydrophobic-interaction chromatography. We used three monoclonal antibodies in two different combinations. In ...

متن کامل

Immunofluorometry of choriogonadotropin by time-resolved fluorescence spectroscopy, with a new europium chelate as label.

We describe a new "sandwich"-type non-isotopic immunoassay for human choriogonadotropin (hCG) in serum. In the assay, hCG is captured by a beta-subunit-specific monoclonal antibody, which is immobilized in a white microtiter well. The sandwich is completed by adding a second biotinylated monoclonal antibody specific for the whole hCG molecule. The degree of binding of biotinylated antibody, whi...

متن کامل

Two-site time-resolved immunofluorometric assay of human insulin.

We describe a two-site "sandwich"-type time-resolved immunofluorometric assay for human insulin, based on use of two monoclonal antibodies with different specificities. The first antibody is immobilized on the surface of microtiter plate strip wells, the other is labeled with Eu3+. Serum samples can be assayed with one incubation step; two incubation steps are required when plasma samples are a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry

دوره 36 4  شماره 

صفحات  -

تاریخ انتشار 1990