Registration of MR prostate images with biomechanical modeling and nonlinear parameter estimation.
نویسندگان
چکیده
Magnetic resonance imaging (MRI) and magnetic resonance spectroscopic imaging (MRSI) have been shown to be very useful for identifying prostate cancers. For high sensitivity, the MRI/MRSI examination is often acquired with an endorectal probe that may cause a substantial deformation of the prostate and surrounding soft tissues. Such a probe is removed prior to radiation therapy treatment. To register diagnostic probe-in magnetic resonance (MR) images to therapeutic probe-out MR images for treatment planning, a new deformable image registration method is developed based on biomechanical modeling of soft tissues and estimation of uncertain tissue parameters using nonlinear optimization. Given two-dimensional (2-D) segmented probe-in and probe-out images, a finite element method (FEM) is used to estimate the deformation of the prostate and surrounding tissues due to displacements and forces resulting from the endorectal probe. Since FEM requires tissue stiffness properties and external force values as input, the method estimates uncertain parameters using nonlinear local optimization. The registration method is evaluated using images from five balloon and five rigid endorectal probe patient cases. It requires on average 37 s of computation time on a 1.6 GHz Pentium-M PC. Comparing the prostate outline in deformed probe-out images to corresponding probe-in images, the method obtains a mean Dice Similarity Coefficient (DSC) of 97.5% for the balloon probe cases and 98.1% for the rigid probe cases. The method improves significantly over previous methods (P < 0.05) with greater improvement for balloon probe cases with larger tissue deformations.
منابع مشابه
Patient-specific Deformation Modelling via Elastography: Application to Image-guided Prostate Interventions
Image-guided prostate interventions often require the registration of preoperative magnetic resonance (MR) images to real-time transrectal ultrasound (TRUS) images to provide high-quality guidance. One of the main challenges for registering MR images to TRUS images is how to estimate the TRUS-probe-induced prostate deformation that occurs during TRUS imaging. The combined statistical and biomec...
متن کاملImage Registration for Prostate MR Spectroscopy Using Biomechanical Modeling and Optimization of Force and Stiffness Parameters
—We develop an image registration system based on biomechanical modeling of the prostate and surrounding tissues to register cancerous tumor locations for targeted prostate brachytherapy treatment planning. Cancerous tumors can be identified using magnetic resonance spectroscopy (MRS) imaging, which is acquired with an endorectal probe that causes significant nonlinear deformation of the prosta...
متن کاملEvaluation of three-dimensional finite element-based deformable registration of pre- and intraoperative prostate imaging.
In this report we evaluate an image registration technique that can improve the information content of intraoperative image data by deformable matching of preoperative images. In this study, pretreatment 1.5 tesla (T) magnetic resonance (MR) images of the prostate are registered with 0.5 T intraoperative images. The method involves rigid and nonrigid registration using biomechanical finite elem...
متن کاملOptimized co-registration method of Spinal cord MR Neuroimaging data analysis and application for generating multi-parameter maps
Introduction: The purpose of multimodal and co-registration In MR Neuroimaging is to fuse two or more sets images (T1, T2, fMRI, DTI, pMRI, …) for combining the different information into a composite correlated data set in order to visualization, re-alignment and generating transform to functional Matrix. Multimodal registration and motion correction in spinal cord MR Neuroimag...
متن کاملRegistration of Magnetic Resonance Images of the Prostate Obtained with an Endorectal Coil to Histological Sections
Introduction Validation of findings from in vivo imaging (e.g. MRI) of the prostate requires precise correlation of histopathological information on a voxel-by-voxel basis, with sub-millimeter accuracy in the absence of identifiable anatomic landmarks. A method is developed to register histopathology sections and in vivo MR images of the prostate obtained with a combination of a phased-array an...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Medical physics
دوره 33 2 شماره
صفحات -
تاریخ انتشار 2006