Primary ciliary dyskinesia: evaluation using cilia beat frequency assessment via spectral analysis of digital microscopy images.
نویسندگان
چکیده
Ciliary beat frequency (CBF) measurements provide valuable information for diagnosing of primary ciliary dyskinesia (PCD). We developed a system for measuring CBF, used it in association with electron microscopy to diagnose PCD, and then analyzed characteristics of PCD patients. The CBF measurement system was based on power spectra measured through digital imaging. Twenty-four patients suspected of having PCD (age 1-19 yr) were selected from a group of 75 children and adolescents with pneumopathies of unknown causes. Ten healthy, nonsmoking volunteers (age ≥ 17 yr) served as a control group. Nasal brush samples were collected, and CBF and electron microscopy were performed. PCD was diagnosed in 12 patients: 5 had radial spoke defects, 3 showed absent central microtubule pairs with transposition, 2 had outer dynein arm defects, 1 had a shortened outer dynein arm, and 1 had a normal ultrastructure. Previous studies have reported that the most common cilia defects are in the dynein arm. As expected, the mean CBF was higher in the control group (P < 0.001) and patients with normal ultrastructure (P < 0.002), than in those diagnosed with cilia ultrastructural defects (i.e., PCD patients). An obstructive ventilatory pattern was observed in 70% of the PCD patients who underwent pulmonary function tests. All PCD patients presented bronchial wall thickening on chest computed tomography scans. The protocol and diagnostic techniques employed allowed us to diagnose PCD in 16% of patients in this study.
منابع مشابه
Disrupted ciliated epithelium shows slower ciliary beat frequency and increased dyskinesia.
Ciliary function studies for the diagnosis of primary ciliary dyskinesia (PCD) are usually performed on nasal brush biopsy samples. It is not uncommon to find disrupted epithelial strips of tissue in these samples, and occasionally throughout a sample. The aim of the present study was to determine if cilia on disrupted ciliated epithelial edges beat with a normal pattern and frequency similar t...
متن کاملAIRWAY BIOLOGY Functional analysis of cilia and ciliated epithelial ultrastructure in healthy children and young adults
Background: There are very few data on normal ciliary beat frequency, beat pattern, and ultrastructure in healthy children and adults. A study was undertaken to define ciliary structure, beat frequency and beat pattern in a healthy paediatric and young adult population. Methods: Ciliated epithelial samples were obtained from 76 children and adult volunteers aged 6 months to 43 years by brushing...
متن کاملFunctional analysis of cilia and ciliated epithelial ultrastructure in healthy children and young adults.
BACKGROUND There are very few data on normal ciliary beat frequency, beat pattern, and ultrastructure in healthy children and adults. A study was undertaken to define ciliary structure, beat frequency and beat pattern in a healthy paediatric and young adult population. METHODS Ciliated epithelial samples were obtained from 76 children and adult volunteers aged 6 months to 43 years by brushing...
متن کاملDevelopment and validation of a method of cilia motility analysis for the early diagnosis of primary ciliary dyskinesia.
BACKGROUND Primary ciliary dyskinesia (PCD) is a clinically uniform entity, but cilia motility and structure can vary between patients, making the diagnostic difficult. The aim of this study was to evaluate the sensitivity and specificity in diagnosing PCD of a system of high-resolution digital high-speed video analysis with proprietary software that we developed for analysis of ciliary motilit...
متن کامل[News in the examination of the ciliary activity in the respiratory tract mucosa].
Ciliary activity assessment attracts a great interest and has undergone dynamic progress since the last decades. The ciliary function is typically impaired in primary ciliary dyskinesia (PCD). The cilia are mostly examined in vitro, the sample is taken away from the nasal mucosa. Digital videomicroscopy is accessible for the cilia observation in vitro and represents a gold standard. Manual read...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of applied physiology
دوره 111 1 شماره
صفحات -
تاریخ انتشار 2011