Illumination of x-rays: the usual lights exposed.

نویسندگان

  • G R J C Blackshaw
  • J A Gostling
  • B N Appleton
  • N Pearce
  • G V Thomas
  • W G Lewis
چکیده

AIMS Faced with pressure of work and limited resource, doctors frequently use the nearest available light to examine x-ray films. The aim of this study was to examine the relative intensities of hospital light sources, and to compare these with the light intensity guidelines (1500 to 3000 candelas) of the British Institute of Radiology. METHODS The relative intensities of seven hospital light sources were examined using a standard light meter at a constant 30 cm from the source. A control group of 10 individual consultant's x-ray viewing boxes were compared with six other ward based light sources. RESULTS Only two light sources approached the British Institute of Radiology light intensity x-ray viewing criteria: the x-ray viewing boxes of consultant radiologists with a median light intensity of 3503 candelas (chi(2)=13.3, df 1; p=0.0001), and daylight from north facing windows with a median of 1464 candelas when overcast (chi(2)=8.571, df 1; p=0.003) and 4669 candelas in sunshine (chi(2)= 6.364, df 1; p=0.0001). CONCLUSION Few hospital light sources met the British Institute of Radiology guidelines. The long held high regard of artists for northern light appears justified even in the environment of a British district general hospital.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Application of characteristic X-rays to measure linear attenuation coefficient of nano-composites used in shielding

Using of X-rays in different industries and especially in medical application is increasing. In this regard, designing of light and efficient protective material based on polymeric nanocomposites and precise study of the effect of adding nanoparticles with different sizes on the X-ray attenuation is necessary. In this study the epoxy nanocomposites with different percentages of copper oxide nan...

متن کامل

An in-vivo study on the energy dependence of X-ray biological effectiveness

Background: The International Commission on Radiological Protection (ICRP) has attributed the same relative risk for X and gamma radiations of all energies. Several studies have proven that the biological effect of low energy photon is more than that of higher ones. The assessment of risks is important due to the wide use of low energy X-rays for mammography screening and other diagnostic appli...

متن کامل

Local Illumination Environments for Direct Lighting Acceleration

Computing high-quality direct illumination in scenes with many lights is an open area of research. This paper presents a world-space caching mechanism called local illumination environments that enables interactive direct illumination in complex scenes on a cluster of off-the-shelf PCs. A local illumination environment (LIE) caches geometric and radiometric information related to direct illumin...

متن کامل

Diagnostic Utility of Chest X-rays in Neonatal Respiratory Distress: Determining the Sensitivity and Specificity

Background: Chest radiography is one of the most usual diagnostic tools for respiratory distress. Objective: The purpose of this study is to assess the specificity, sensitivity and clinical value of chest radiography of neonates with respiratory distress.Patients and Methods: A descriptive- analytical study was conducted on 102 neonates that were in neonatal intensive care unit of Imam Reza and...

متن کامل

A three-year survey of film badge service performance in Iran

An extensive study was undertaken to Investigate on the overall film badge service performance with which occupational radiation, exposures are reported In Iran, The study involved the analysis of film badges exposed to x-and gamma rays and beta particles. For test exposures, x-rays between 60 and 140 KVPCo-60 gamma radiation and Sr-90 beta particles were used. The actual delivered dose equival...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Postgraduate medical journal

دوره 79 928  شماره 

صفحات  -

تاریخ انتشار 2003