Urine collection in the freely moving rat: reliability for measurement of short-term renal effects.
نویسندگان
چکیده
Studies on short-term renal responses to (pharmacological) intervention require accurate and multiple collection of urine samples. Several invasive techniques have been described for frequent urine collection of the conscious rat, each having their own limitations. No data are available about the feasibility of the spontaneously voiding, freely moving rat for this purpose. In the present study, bladder voidings of six rats were time-registered and collected separately for several days. The data show a considerable 24-h variation coefficient of both the voided volume and the bladder collection time with a poor correlation between the two parameters. Forced diuresis induced by continuous i.v. infusion (2 ml/h) increased the frequency of urine voiding and thus the time-resolution of the urine-production pattern. However, this method failed to reduce the variation coefficient of the voided volume, the collection time, and the correlation between the two parameters. The fact that variations in creatinine excretion paralleled the variation in urinary flow suggests that both phenomena are likely be due to incomplete bladder emptying. Correction for this incomplete bladder collection, using the creatinine excretion, indeed reduced the variation coefficient of sodium excretion successfully from 61 +/- 17% to 29 +/- 5% during normal diuresis and from 56 +/- 19% to 22 +/- 6% during forced diuresis. In conclusion, the spontaneously voiding, freely moving rat can be used for short-term renal response studies if the collected urine samples are corrected for incomplete bladder emptying using urinary creatinine concentrations. This procedure allows the detection of changes in a urinary parameter if this exceeds a 40% deviation of the normal value.
منابع مشابه
The state dependency effect of morphine on memory by behavioral and electrophysiological methods in freely moving rats
Endogenous opioid system agonists exert amnestic effects in different models of memory. It has been suggested that these amnestic effects may be linked indirectly to state-dependent learning. Accordingly pre-training administration of morphine can impair the retrieval of learned tasks in a state dependent manner, which is reversible by pre test morphine administration. In this study, state depe...
متن کاملThe state dependency effect of morphine on memory by behavioral and electrophysiological methods in freely moving rats
Endogenous opioid system agonists exert amnestic effects in different models of memory. It has been suggested that these amnestic effects may be linked indirectly to state-dependent learning. Accordingly pre-training administration of morphine can impair the retrieval of learned tasks in a state dependent manner, which is reversible by pre test morphine administration. In this study, state depe...
متن کاملEffects of Neonatal C-Fiber Depletion on Interaction between Neocortical Short-Term and Long-Term Plasticity
Introduction: The primary somatosensory cortex has an important role in nociceptive sensory-discriminative processing. Altered peripheral inputs produced by deafferentation or by long-term changes in levels of afferent stimulation can result in plasticity of cortex. Capsaicin-induced depletion of C-fiber afferents results in plasticity of the somatosensory system. Plasticity includes short-term...
متن کاملP-7: Effects of Long-Term Exposure to Radiofrequency Radiations Emitted by Common Mobile Jammers on Sperm Quality Parameters in Rat
Background Exposure to electromagnetic fields (EMFs) by using electrical machines, tools, industrial instruments, power lines, and communications devices has occurred as a result of technological developments and is causing a threat to normal lives. The aim of this study was to evaluate the effects of long-term exposure to radiofrequency (RF) radiations emitted by mobile jammers.on sperm qualit...
متن کاملDetermination of 5-Hydroxymethyl-2-furaldehyde of Crude and Processed Fructus Corni in Freely Moving Rats Using In Vivo Microdialysis Sampling and Liquid Chromatography
The purpose of this study was to develop a sensitive and fast microdialysis coupled with high-performance liquid chromatographic (HPLC) method for determination of 5-hydroxymethyl-2-furaldehyde (5-HMF) in free-moving rats after i.g. administration of the aqueous extract of crud Fructus corni and its processed products of jiuzheng pin (JZP). The concentration of 5-HMF in free-movi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of pharmacological and toxicological methods
دوره 38 1 شماره
صفحات -
تاریخ انتشار 1997