Development and Validation of Reverse Phase High Performance Chromatography Method for Determination of Olanzapine in Microsample Rat Plasma: Application to Preclinical Pharmacokinetic Study

نویسندگان

  • Fahad Pervaiz
  • Mahmood Ahmad
  • Muhammad Usman Minhas
چکیده

Purpose: To develop a sensitive and validated reverse phase-high performance liquid chromatographic (RP-HPLC) method for quantification of olanzapine in micro-sample of rat plasma using UV detection. Methods: A single oral dose of olanzapine (7 mg/kg) was given to overnight fasted rats (n = 6). Rat plasma samples containing the drug were extracted by liquid-liquid extraction using a combination of dichloromethane: n-hexane (80:20). A reverse phase chromatographic column C18 hypersil-BDS was used for chromatographic separation with a mobile phase consisting of 50 mM phosphate buffer pH 5.5, acetonitrile and methanol (50:30:20, v/v/v) pumped at a flow rate of 1.2 ml/min. Olanzapine was measured using ultraviolet (UV) detection at 214 nm. The method was validated for precision and accuracy. Results: Separation of compounds of interest was not affected by endogenous interference. Good linearity within the concentration range of 1 500 ng/ml in rat plasma was obtained with coefficient of regression (r) of 0.9986. Liquid-liquid extraction produced comparable recovery to solid phase extraction. Retention time of olanzapine and internal standard (fluoxetine) was 5.0 and 13.4 min, respectively. Lowest limit of quantification (LLOQ) was 1 ng/ml while inter-day and intra-day precision was < 12.5 and 5.1 %, respectively. Accuracy of the method was between 94 and 105 % and the variation of results between two analysts was not significant (p = 0.626). Mean maximum plasma concentration (Cmax) of olanzapine was 412.7 ng/ml, time to attain maximum plasma concentration (tmax) was 1 h and half life (t1/2) was 2.54 h. Conclusion: The proposed method has been successfully validated for precision and accuracy that are within the limits of U.S. Food and Drug Administration (FDA)’s guidance for bioanalyitcal assay validation. The method was successfully applied to preclinical pharmacokinetic analysis of olanzapine in rats.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Rapid, Simple, Liquid Chromatographic-Electrospray Ionization, Ion Trap Mass Spectrometry Method for the Determination of Finasteride in Human Plasma and its Application to Pharmacokinetic Study

     A fast, accurate, sensitive, selective and reliable method using reversed-phase high performance liquid chromatography coupled to electrospray ionization ion trap mass spectrometry was developed and validated for the determination of finasteride in human plasma. After protein precipitation with perchloric acid, satisfactory separation was achieved on a Zorbax Eclipse® C8 analytical column u...

متن کامل

A Rapid, Simple, Liquid Chromatographic-Electrospray Ionization, Ion Trap Mass Spectrometry Method for the Determination of Finasteride in Human Plasma and its Application to Pharmacokinetic Study

     A fast, accurate, sensitive, selective and reliable method using reversed-phase high performance liquid chromatography coupled to electrospray ionization ion trap mass spectrometry was developed and validated for the determination of finasteride in human plasma. After protein precipitation with perchloric acid, satisfactory separation was achieved on a Zorbax Eclipse® C8 analytical column u...

متن کامل

High-Performance Liquid Chromatographic Determination of Rivastig-mine in Human Plasma for Application in Pharmacokinetic Studies

A simple and reproducible HPLC method with spectrophotometric detection was developed for determination of rivastigmine in human plasma. Liquid-liquid extraction of rivastigmine and donepezil (as internal standard) from plasma samples was performed with 1-butanol/n-hexane (2:98 v/v) in alkaline condition followed by back-extraction into diluted acetic acid. Chromatography was carried out using ...

متن کامل

High-Performance Liquid Chromatographic Determination of Rivastig-mine in Human Plasma for Application in Pharmacokinetic Studies

A simple and reproducible HPLC method with spectrophotometric detection was developed for determination of rivastigmine in human plasma. Liquid-liquid extraction of rivastigmine and donepezil (as internal standard) from plasma samples was performed with 1-butanol/n-hexane (2:98 v/v) in alkaline condition followed by back-extraction into diluted acetic acid. Chromatography was carried out using ...

متن کامل

اندازه‌گیری مبودیپین در مایعات بیولوژیک با روش HPLC و کاربرد این دارو در مطالعه فارماکوکینتیک در موش صحرایی An HPLC Method for Determination of Mebudipine in Biological Fluids in Rats and its Application in Pharmacokinetic Study

        Background & Aim: Mebudipine is a calcium antagonist drug which is used to treat blood pressure. A new high performance liquid chromatography(HPLC) system for the determination of a new 1, 4-dihydropyridine, mebudipine, in rat plasma and other biological fluids was developed in this study for the first time. Materials & Methods: To 1 ml of rat plasma and/or other biological fluids, 0.5 ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015