Improvements to the calibration of the MST Thomson scattering diagnostic.
نویسندگان
چکیده
Calibration of the Madison Symmetric Torus Thomson scattering system has been refined to improve temperature fluctuation measurements. Multiple avalanche photodiodes have been directly calibrated for use as reference detectors during calibration, improving accuracy and ease of use. From the absolute calibration we calculate corrections to the gain for variation in detector operating temperature. We also measure the spatial uniformity of detector responsivity for several photodiodes, and present a method of accounting for non-uniformity in the calibration process. Finally, the gain and noise enhancement are measured at multiple wavelengths to improve temperature and uncertainty measurements.
منابع مشابه
Identification and mitigation of stray laser light in the Thomson scattering system on the Madison Symmetric Torus (MST).
The Thomson scattering diagnostic on the Madison Symmetric Torus (MST) records excessive levels of stray Nd:YAG laser light. Stray light saturates the 1064 nm spectral channel in all polychromators, which prevents absolute electron density measurements via Rayleigh scattering calibration. Furthermore, stray light contaminates adjacent spectral channels for r/a ≥ 0.75, which renders the diagnost...
متن کاملUpgrades to improve the usability, reliability, and spectral range of the MST Thomson scattering diagnostic.
The Thomson scattering diagnostic on MST records both equilibrium and fluctuating electron temperature with a range capability of 10 eV-5 keV. Standard operation with two modified commercial Nd:YAG lasers allows measurements at rates of 1 kHz-25 kHz. Several subsystems of the diagnostic are being improved. The power supplies for the avalanche photodiode detectors (APDs) that record the scattere...
متن کاملA Self-calibration Method for the Edge Thomson Scattering Diagnostic in ITER
Calibration of spectral transmissivity of the collection and transmission optics is one of the most crucial issues for the Thomson scattering diagnostic system. Radioactivation of the vacuum vessel in ITER makes it difficult to calibrate spectral transmissivity in areas near the vacuum vessel. By using an additional calibration laser whose wavelength differs from those of the diagnostic laser a...
متن کاملCorrection of the spectral calibration of the Joint European Torus core light detecting and ranging Thomson scattering diagnostic using ray tracing.
This work isolated the cause of the observed discrepancy between the electron temperature (T(e)) measurements before and after the JET Core LIDAR Thomson Scattering (TS) diagnostic was upgraded. In the upgrade process, stray light filters positioned just before the detectors were removed from the system. Modelling showed that the shift imposed on the stray light filters transmission functions d...
متن کاملHigh-repetition-rate pulse-burst laser for Thomson scattering on the MST reversed-field pinch
A new, high-repetition-rate pulse-burst laser system for the MST Thomson scattering diagnostic has operated with 2 J pulses at repetition rates up to 75 kHz within a burst. The 1064 nm laser currently employs a q-switched, diode pumped Nd:YVO4 master oscillator, four Nd:YAG amplifier stages, and a Nd:glass amplifier, with plans for an additional Nd:glass amplifier. The laser can maintain 1.5–2 ...