Integrated electroanatomic mapping with three-dimensional computed tomographic images for real-time guided ablations.
نویسندگان
چکیده
BACKGROUND New ablation strategies for atrial fibrillation or nonidiopathic ventricular tachycardia are increasingly based on anatomic consideration and require the placement of ablation lesions at the correct anatomic locations. This study sought to evaluate the accuracy of the first clinically available image integration system for catheter ablation on 3-dimensional (3D) computed tomography (CT) images in real time. METHODS AND RESULTS After midline sternotomy, 2.3-mm CT fiducial markers were attached to the epicardial surface of each cardiac chamber in 9 mongrel dogs. Detailed 3D cardiac anatomy was reconstructed from contrast-enhanced, high-resolution CT images and registered to the electroanatomic maps of each cardiac chamber. To assess accuracy, targeted ablations were performed at each of the fiducial markers guided only by the reconstructed 3D images. At autopsy, the position error was 1.9+/-0.9 mm for the right atrium, 2.7+/-1.2 mm for the right ventricle, 1.8+/-1.0 mm for the left atrium, and 2.3+/-1.1 mm for the left ventricle. To evaluate the system's guidance of more complex clinical ablation strategies, ablations of the cavotricuspid isthmus (n=4), fossa ovalis (n=4), and pulmonary veins (n=6) were performed, which resulted in position errors of 1.8+/-1.5, 2.2+/-1.3, and 2.1+/-1.2 mm, respectively. Retrospective analysis revealed that a combination of landmark registration and the target chamber surface registration resulted in <3 mm accuracy in all 4 cardiac chambers. CONCLUSIONS Image integration with high-resolution 3D CT allows accurate placement of anatomically guided ablation lesions and can facilitate complex ablation strategies. This may provide significant advantages for anatomically based procedures such as ablation of atrial fibrillation and nonidiopathic ventricular tachycardia.
منابع مشابه
Three-dimensional ultrasound for image-guided mapping and intervention: methods, quantitative validation, and clinical feasibility of a novel multimodality image mapping system.
BACKGROUND Multiple factors create discrepancies between electroanatomic maps and merged, preacquired computed tomographic images used in guiding atrial fibrillation ablation. Therefore, a Carto-based 3D ultrasound image system (Biosense Webster Inc) was validated in an animal model and tested in 15 atrial fibrillation patients. METHODS AND RESULTS Twelve dogs underwent evaluation using a new...
متن کاملMandibular Dimensional Changes with aging in Three Dimensional Computed Tomographic Study in 21 to 50 Year old Men and Women
Introduction: Raising the knowledge of skeletal and soft tissue changes with aging has been highly essential due to an increasing demand for aesthetic facial surgery following aging. The aim of this study is to evaluate the three dimensional computed tomographic images and process of changes in mandible with aging. Materials and Methods: In this descriptive study, the facial CT scans were obta...
متن کاملThree-dimensional image integration: a first experience with guidance of atrial fibrillation ablations.
The treatment of atrial fibrillation (AF) can be challenging, with a rate control strategy not being optimal for all patients and antiarrhythmic drugs frequently ineffective and possessing serious adverse effects. A fluoroscopic or electroanatomic catheter-based approach is rapidly becoming one of the preferred treatments of AF.1-3 However, success rates are still not ideal and complications du...
متن کاملPotency of integrating three-dimensional cardiac magnetic resonance imaging into electroanatomic mapping to perform catheter ablation in pediatrics
Background Radio-frequency catheter ablation (RFCA) in children is difficult because the size of heart chamber change with age and the catheter made for adults is not appropriate for a child. Three-dimensional (3D) images for electroanatomic mapping (EAM) have been used to create from images of multi-detector computed tomography (MDCT) which need to perform entailed by contrast medium injection...
متن کاملElectroanatomic mapping and radiofrequency ablation of porcine left atria and atrioventricular nodes using magnetic resonance catheter tracking.
BACKGROUND The MRI-compatible electrophysiology system previously used for MR-guided left ventricular electroanatomic mapping was enhanced with improved MR tracking, an MR-compatible radiofrequency ablation system and higher-resolution imaging sequences to enable mapping, ablation, and ablation monitoring in smaller cardiac structures. MR-tracked navigation was performed to the left atrium (LA)...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Circulation
دوره 113 2 شماره
صفحات -
تاریخ انتشار 2006