Blood flow to hindquarters of steers measured by transit time ultrasound and indicator dilution.

نویسندگان

  • J H Eisemann
  • G B Huntington
  • C L Ferrell
چکیده

The objective was to compare blood flow to the hindquarters of steers measured by transit time ultrasound with blood flow determined by indicator (p-aminohippurate) dilution. Five Hereford steers had ultrasonic flow probes on the abdominal aorta and catheters in the abdominal aorta and inferior vena cava inserted through both sets of circumflex iliac vessels. Indicator was infused continuously into the abdominal aorta through both arterial catheters simultaneously, then through each of the arterial catheters in succession. Samples of blood from the inferior vena cava and jugular vein were taken during infusion for measurement of p-aminohippurate. Blood flow determined by the ultrasonic flow probe was averaged over each blood sampling interval. Compared with the ultrasonic flow probe there was no difference in mean blood flow measured by p-aminohippurate, regardless of method of infusion. Correlation of individual values between ultrasound and p-aminohippurate was .87 when p-aminohippurate was infused into both arterial catheters, .44 when p-aminohippurate was infused into the left arterial catheter, and .78 when p-aminohippurate was infused into the right arterial catheter. The respective ranges for ultrasonic measurements and p-aminohippurate were 3.62 to 10.99 L/min and 2.25 to 30.43 L/min. Although means by the two methods do not differ, there is a greater range and incidence of occasional high values with p-aminohippurate dilution.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Technical note: measuring portal blood flow in sheep using an ultrasonic transit time flow probe.

Our objective was to validate the use of an ultrasonic transit-time flowmeter for the measurement of portal blood flow (PBF) in sheep. Data recorded with this technique were compared with those obtained with an indicator dilution method, and probes were calibrated in vivo. Wethers were fitted with catheters in the portal, jejunal, and ruminal veins and in a mesenteric artery. Ultrasonic flow pr...

متن کامل

Volume quantification by contrast-enhanced ultrasound: an in-vitro comparison with true volumes and thermodilution

BACKGROUND Contrast-enhanced ultrasound (CEUS) has recently been proposed as a minimally- invasive, alternative method for blood volume measurement. This study aims at comparing the accuracy of CEUS and the classical thermodilution techniques for volume assessment in an in-vitro set-up. METHODS The in-vitro set-up consisted of a variable network between an inflow and outflow tube and a roller...

متن کامل

Validation in the sheep of an ultrasound velocity dilution technique for haemodialysis graft flow.

BACKGROUND A simple, rapid, inexpensive method for measuring the flow in a patient's vascular access would permit routine monitoring during haemodialysis, and hence provide information of access graft deterioration sufficiently early to increase the success of minimally invasive remedial procedures. This paper reports the validation of such a method in animals. METHODS A PTFE graft was implan...

متن کامل

Evaluation of Roentgen cinedensitometry for flow measurement in models and in the intact circulation.

SUMMARY The flow of blood in vitro and in the carotid artery of the dog was calculated by a new cinedensitometric technique and compared with the flow as measured simultaneously by graduated cylinder and stopwatch. Cineangiographic films were projected onto a frosted screen and the light intensity was measured at two neighboring cross sections of the vessel in question. The passage of the contr...

متن کامل

Videodensitometric Methods for Cardiac Output Measurements

Cardiac output is often measured by indicator dilution techniques, usually based on dye or cold saline injections. Developments of more stable ultrasound contrast agents (UCA) are leading to new noninvasive indicator dilution methods. However, several problems concerning the interpretation of dilution curves as detected by ultrasound transducers have arisen. This paper presents a method for blo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of dairy science

دوره 70 7  شماره 

صفحات  -

تاریخ انتشار 1987