Do Diametric Measurements Provide Sufficient and Reliable Tumor Assessment? An Evaluation of Diametric, Areametric, and Volumetric Variability of Lung Lesion Measurements on Computerized Tomography Scans

نویسندگان

  • Aaron Frenette
  • Joshua Morrell
  • Kirk Bjella
  • Edward Fogarty
  • James Beal
  • Vijay Chaudhary
چکیده

Diametric analysis is the standard approach utilized for tumor measurement on medical imaging. However, the availability of newer more sophisticated techniques may prove advantageous. An evaluation of diameter, area, and volume was performed on 64 different lung lesions by three trained users. These calculations were obtained using a free DICOM viewer and standardized measuring procedures. Measurement variability was then studied using relative standard deviation (RSD) and intraclass correlation. Volumetric measurements were shown to be more precise than diametric. With minimal RSD and variance between different users, volumetric analysis was demonstrated as a reliable measurement technique. Additionally, the diameters were used to calculate an estimated area and volume; thereafter the estimated area and volume were compared against the actual measured values. The results in this study showed independence of the estimated and actual values. Estimated area deviated an average of 43.5% from the actual measured, and volume deviated 88.03%. The range of this variance was widely scattered and without trend. These results suggest that diametric measurements cannot be reliably correlated to actual tumor size. Access to appropriate software capable of producing volume measurements has improved drastically and shows great potential in the clinical assessment of tumors. Its applicability merits further consideration.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluating variability in tumor measurements from same-day repeat CT scans of patients with non-small cell lung cancer.

PURPOSE To evaluate the variability of tumor unidimensional, bidimensional, and volumetric measurements on same-day repeat computed tomographic (CT) scans in patients with non-small cell lung cancer. MATERIALS AND METHODS This HIPAA-compliant study was approved by the institutional review board, with informed patient consent. Thirty-two patients with non-small cell lung cancer, each of whom u...

متن کامل

Synthetic Lung Tumor Data Sets for Comparison of Volumetric Algorithms

We present a set of synthetic lung tumor data in which synthetic tumors of known volume are embedded in clinical lung computerized tomographic (CT) data in different background settings in the lung. Because the change in pulmonary nodules over time is an important indicator of lung tumor malignancy, it is important to be able to accurately measure changes in tumor size from measurements made at...

متن کامل

Variability in response assessment in solid tumors: effect of number of lesions chosen for measurement.

PURPOSE This study was performed to systematically evaluate the variability in tumor response assessments that occurs depending on how many tumor deposits are selected for measurement at imaging. EXPERIMENTAL DESIGN The two largest perpendicular diameters of all tumor deposits in 36 patients were measured on computed tomography scans obtained at baseline and first posttherapy follow-up. A com...

متن کامل

The Accuracy of Cone-beam Computerized Tomography Linear Measurements in Human Dry Mandible

Background & Aims: The aim of this study was to evaluate the accuracy of Cone-beam Computerized Tomography (CBCT) linear measurements in dry mandibles by comparing them with direct measurements. Methods: Two human dry mandibles were used in this study. Thirteen sites were selected on each mandible. Specimens were scanned by CBCT and linear measurements were made using Planmeca Romexis 2.3.0.R s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 2015  شماره 

صفحات  -

تاریخ انتشار 2015