Radioimmunoassay of digoxin: an intercomparison of results with three methods.

نویسندگان

  • S Gutcho
  • H McCarter
  • R Rapun
چکیده

The radioimmunoassay of digoxin has been examined by comparing RIA data obtained by a clinical laboratory using the method of Smith et al. [New Engi. J. Med. 281, 1212 (1969)] with data obtained in a laboratory using commercially produced [3H]digoxin and [1251]digoxin kits. Correlations between clinical laboratory data and the results with each kit and correlation between kits are presented. The effects of digoxin-free sera and plasmas on standard curves have been examined.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intercomparison of seven radioimmunoassay kits and a fluorescence polarization immunoassay kit for digoxin.

Samples from 33 patients being treated with digoxin and three concentrations of control material were analyzed for this drug by use of seven radioimmunoassay (RIA) kits and an automated fluorescence polarization immunoassay (FPIA) system. CVs ranged from 2.4 to 6.4% for the FPIA system and from 4.6 to 7.4% for two RIA methods. In the analysis of between-method variability of RIA kits, CVs range...

متن کامل

Abbott TDx, Dade Stratus, and Du Pont aca automated digoxin immunoassays compared with a reference radioimmunoassay method.

Automated digoxin immunoassays with the Abbott TDx, Dade Stratus, and Du Pont aca were evaluated against an RIA similar to the Centers for Disease Control Candidate Reference Method. All three automated methods correlated poorly with the reference method. Particularly disconcerting were the falsely increased values (up to 0.6 micrograms/L) obtained by the Stratus for blank specimens. We discuss...

متن کامل

Improved micro-radioimmunoassay of digoxin in serum, with use of 125I-labeled digoxin.

A micro-radioimmunoassay of 125I-labeled digoxin is described in which 10-mul rather than 50-mul aliquots of sera are required. The method is a modification of a simplified, rapid, and accurate procedure, which is commercially available as a kit. There is excellent correlation between results by these two methods, in which lyophilized digoxin standards and insoluble antibody polymer are used. T...

متن کامل

Assessment of Abnormal Serum Digoxin Concentration

ABSTRACT Cardiac glycosides have been used in the management of heart failure for more than 200 years and remain the only drug currently available for Long-term ambulatory use that have positive inotropic effect. The relatively narrow therapeutic- index of cardiac glycosides renders them particularly difficult to use, and the clinician should have a detailed understanding of the actions and ph...

متن کامل

Microencapsulated antibodies in radioimmunoassay--I. Determination of digoxin.

We describe the application of the microencapsulated-antibody technique to the radioimmunoassay of digoxin in serum. Droplets of emulsified rabbit antibody are microencapsulated in a semipermeable nylon membrane by an interfacial polymerization technique. The antibody microcapsules are incubated with 125I-labeled digoxin and unlabeled digoxin for 15 min at 37 degrees C, then free and bound digo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 19 9  شماره 

صفحات  -

تاریخ انتشار 1973