Role of uterine forces in intrauterine device embedment, perforation, and expulsion

نویسندگان

  • Norman D Goldstuck
  • Dirk Wildemeersch
چکیده

BACKGROUND The purpose of this study was to examine factors that could help reduce primary perforation during insertion of a framed intrauterine device (IUD) and to determine factors that contribute in generating enough uterine muscle force to cause embedment and secondary perforation of an IUD. The objective was also to evaluate the main underlying mechanism of IUD expulsion. METHODS We compared known IUD insertion forces for "framed" devices with known perforation forces in vitro (hysterectomy specimens) and known IUD removal forces and calculated a range of possible intrauterine forces using pressure and surface area. These were compared with known perforation forces. RESULTS IUD insertion forces range from 1.5 N to 6.5 N. Removal forces range from 1 N to 5.8 N and fracture forces from 8.7 N to 30 N depending upon device. Measured perforation forces are from 20 N to 54 N, and calculations show the uterus is capable of generating up to 50 N of myometrial force depending on internal pressure and surface area. CONCLUSION Primary perforation with conventional framed IUDs may occur if the insertion pressure exceeds the perforation resistance of the uterine fundus. This is more likely to occur if the front end of the inserter/IUD is narrow, the passage through the cervix is difficult, and the procedure is complex. IUD embedment and secondary perforation and IUD expulsion may be due to imbalance between the size of the IUD and that of the uterine cavity, causing production of asymmetrical uterine forces. The uterine muscle seems capable of generating enough force to cause an IUD to perforate the myometrium provided it is applied asymmetrically. A physical theory for IUD expulsion and secondary IUD perforation is given.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

role of uterine forces in intrauterine device embedment , perforation , and expulsion norman

(unported, v3.0) License. The full terms of the License are available at http://creativecommons.org/licenses/by-nc/3.0/. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. Permissions beyond the scope of the License are administered by Dove Medical Press Limited. Information on how to request pe...

متن کامل

The Role of Three Dimensional Transvaginal Ultrasound in Detection of Intrauterine Device Displacement in Post Caesarean Section: A Case Report

Intrauterine Devices (IUDs) are used as an efficient and inexpensive method of contracep¬tion. Contraceptive efficacy depends on the intrauterine location of IUD and intrauterine displacement of the IUD leads to decreased contraceptive efficacy. Expulsion of IUD and its penetration into myometrium is one of the complications of IUD. In cases where IUDs are not detected by ultrasound method, in ...

متن کامل

Ultrasonography of intrauterine devices

The intrauterine device (IUD) is gaining popularity as a reversible form of contraception. Ultrasonography serves as first-line imaging for the evaluation of IUD position in patients with pelvic pain, abnormal bleeding, or absent retrieval strings. This review highlights the imaging of both properly positioned and malpositioned IUDs. The problems associated with malpositioned IUDs include expul...

متن کامل

Timing of copper intrauterine device insertion after medical abortion: a randomized controlled trial.

OBJECTIVE To compare intrauterine device (IUD) use at 6 months in women randomized to receive an intrauterine copper contraceptive 1 week compared with 1 month after medical abortion. METHODS We recruited women undergoing medical abortion with mifepristone and misoprostol and choosing the copper IUD for contraception. We randomly assigned participants to "immediate" insertion 1 week after mif...

متن کامل

Evaluation of Safety, Efficacy, and Expulsion of Post-Placental and Intra-Cesarean Insertion of Intrauterine Contraceptive Devices (PPIUCD).

BACKGROUND This study examines to describe the factors associated with acceptability of immediate PPIUCD insertion in women according to their socio-demographic and obstetrics characteristics, and future pregnancy desires and to determine the rates of uterine perforation, expulsion, pelvic infection, lost strings and displacement following PPIUCD insertion among the acceptors by 6 to 18 months....

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2014