PCDD/F and other micropollutants in MSWI crude gas and ashes during plant start-up and shut-down processes.

نویسندگان

  • Katja Neuer-Etscheidt
  • Hermann O Nordsieck
  • Yongbo Liu
  • Antonius Kettrup
  • Ralf Zimmermann
چکیده

Nonstationary combustion conditions at municipal solid waste incineration (MSWI) plants cause increased crude gas concentrations of polychlorinated dibenzo-p-dioxins (PCDD), polychlorinated dibenzofurans (PCDF), and other products of incomplete combustion (PIC). Such transient conditions occur, e.g., during and after start-up processes in MSWI plants. The start-up and shut-down processes of a MSWI plant were investigated in detail. PCDD/F and other PIC concentrations were determined in the crude gas, in the boiler ash, and in the ash from the electrostatic precipitator (ESP ash), with the outcome that only the start-up procedure significantly affected the concentrations of the organic pollutants in the flue gas and in the ESP ash. The shut-down procedure was evaluated as less problematic for the concentration of the organic pollutants. Moreover the concentration of the PCDD/F and other PIC in the boiler ash was determined as not influenced by shut-down and start-up processes. The homologue profiles and the congener patterns as well as the PCDF/PCDD ratio in the flue gas and in the ESP ash change during MSWI start-up. The changing patterns point at a transition from dominant de novo synthesis to precursor synthesis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Emission characteristics and vapour/particulate phase distributions of PCDD/F in a hazardous waste incinerator under transient conditions

Polychlorinated dibenzo-p-dioxin and polychlorinated dibenzofuran (PCDD/F) emission characteristics and vapour/particulate phase partitions under three continued operation conditions, i.e. shut-down, start-up and after start-up, were investigated by sampling stack gas. The results indicated that the PCDD/F emission levels were 0.40-18.03 ng I-TEQ Nm-3, much higher than the annual monitoring lev...

متن کامل

Influence of start-up on PCDD/F emission of incinerators.

This study aims to evaluate the influence of start-up on polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/Fs) concentration in the stack flue gas of incinerators and its contributing PCDD/F emission. The PCDD/F emission of the first sample among three consecutive stack flue gas samples of five intermittent incinerators, which sampled at a stable combustion condition aft...

متن کامل

Assessment of the PCDD/F fate from MSWI residue used in road construction in France.

MSWI fly ash is susceptible to contain high amount of polychlorinated dibenzo-dioxins and polychlorinated dibenzo-furans. However, the use of MSWI residue for road construction started in France at a period when MSWI Bottom Ash and MSWI fly ash were not separated. From four old road sites, MSWI residue, road soils, reference soils and geo-textiles were sampled and their PCDD/F contents were ana...

متن کامل

PCDD/F levels in the neighbourhood of a municipal solid waste incinerator after introduction of technical improvements in the facility.

In 1998 and 1999, the concentrations of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) were determined in soil and herbage samples collected in the vicinity of an old municipal solid waste incinerator (MSWI) (S. Adrià del Besòs, Barcelona, Spain). Just after the 1999 collection, an adaptation to the EU legislation on pollutant emissions from the stack was carried out in this faci...

متن کامل

Long-term study of environmental levels of dioxins and furans in the vicinity of a municipal solid waste incinerator.

From 1975 to 2004, a municipal solid waste incinerator (MSWI) was operating in Montcada (Barcelona, Catalonia, Spain). Because of the potential health risks derived from emission of pollutants by the facility, especially polychlorinated dibenzo-p-dioxins (PCDDs) and dibenzofurans (PCDFs), a long-term monitoring program focused on measuring the environmental levels of PCDD/Fs near the facility, ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Environmental science & technology

دوره 40 1  شماره 

صفحات  -

تاریخ انتشار 2006