Reduced residual conduction gaps and favourable outcome in contact force-guided circumferential pulmonary vein isolation

نویسندگان

  • Taihei Itoh
  • Masaomi Kimura
  • Hirofumi Tomita
  • Shingo Sasaki
  • Shingen Owada
  • Daisuke Horiuchi
  • Kenichi Sasaki
  • Yuji Ishida
  • Takahiko Kinjo
  • Ken Okumura
چکیده

AIMS Although contact force (CF)-guided circumferential pulmonary vein isolation (CPVI) for paroxysmal atrial fibrillation (PAF) is useful, AF recurrence at long-term follow-up still remains to be resolved. The purpose of this study was to assess safety and efficacy of CF-guided CPVI and to compare residual conduction gaps during CPVI and long-term outcome between the conventional (non-CF-guided) and the CF-guided CPVI. METHODS AND RESULTS We studied the 50 consecutive PAF patients undergoing CPVI by a ThermoCool EZ Steer catheter (conventional group, mean age 61 ± 10 years) and the other 50 consecutive PAF patients by a ThermoCool SmartTouch catheter (CF group, 65 ± 11 years). The procedure parameters and residual conduction gaps during CPVI, and long-term outcome for 12 months were compared between the two groups. Circumferential pulmonary vein isolation was successfully accomplished without any major complications in both groups. Total procedure and total fluoroscopy times were both significantly shorter in the CF group than in the conventional group (160 ± 30 vs. 245 ± 61 min, P < 0.001, and 17 ± 8 vs. 54 ± 27 min, P < 0.001, respectively). Total number of residual conduction gaps was significantly less in the CF group than in the conventional group (2.7 ± 1.7 vs. 6.3 ± 2.7, P < 0.05). The AF recurrence-free rates after CPVI during 12-month follow-up were 96% (48/50) in the CF group and 82% (41/50) in the conventional group (P = 0.02 by log rank test). Multivariate Cox regression analysis further supported this finding. CONCLUSION Contact force-guided CPVI is safe and more effective in reducing not only the procedure time but also the AF recurrence than the conventional CPVI, possibly due to reduced residual conduction gaps during CPVI procedure.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

CMR-guided targeting of gaps after initial pulmonary vein isolation.

SEE PAGE 653 P ulmonary vein (PV) isolation has become an established treatment for symptomatic drugrefractory atrial fibrillation (AF). However, the efficacy of AF ablation is suboptimal, with a majority of failures resulting from discontinuities in circumferential ablation sets for PV isolation. The presence of PV entrance and exit conduction block serves as a surrogate of complete circumfere...

متن کامل

Circumferential pulmonary vein isolation: wait or stop early after initial successful pulmonary vein isolation?

AIMS Circumferential pulmonary vein isolation (PVI) is the current standard of interventional atrial fibrillation (Afib) therapy. However, recurrence rate of Afib varies considerably after ablation between different series and is mainly attributed to the recovery of pulmonary vein (PV) conduction after initial successful PVI. STUDY HYPOTHESIS Waiting longer during the initial PVI procedure an...

متن کامل

EFFICAS II: optimization of catheter contact force improves outcome of pulmonary vein isolation for paroxysmal atrial fibrillation

AIMS A challenge of pulmonary vein isolation (PVI) in catheter ablation for paroxysmal atrial fibrillation (PAF) is electrical reconnection of the PV. EFFICAS I showed correlation between contact force (CF) parameters and PV durable isolation but no prospective evaluation was made. EFFICAS II was a multicentre study to prospectively assess the impact of CF guidance for an effective reduction of...

متن کامل

Lessons from dissociated pulmonary vein potentials: entry block implies exit block

AIMS Prior reports using pacing manoeuvres, demonstrated an up to 42% prevalence of residual pulmonary vein to left atrium (PV-LA) exit conduction after apparent LA-PV entry block. We aimed to determine in a two-centre study the prevalence of residual PV-LA exit conduction in the presence of unambiguously proven entry block and without pacing manoeuvres. METHODS AND RESULTS Of 378 patients, 1...

متن کامل

Optimal Force–Time Integral for Pulmonary Vein Isolation According to Anatomical Wall Thickness Under the Ablation Line

BACKGROUND Low contact force and force-time integral (FTI) during catheter ablation are associated with ineffective lesion formation, whereas excessively high contact force and FTI may increase the risk of complications. We sought to evaluate the optimal FTI for pulmonary vein (PV) isolation based on atrial wall thickness under the ablation line. METHODS AND RESULTS Contact force parameters a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 18  شماره 

صفحات  -

تاریخ انتشار 2016