Chronic exposure of pigs to airborne dust and endotoxins in an environmental chamber: technical note.

نویسندگان

  • B Urbain
  • J F Prouvost
  • D Beerens
  • O Michel
  • B Nicks
  • M Ansay
  • P Gustin
چکیده

A new experimental setup was developed to expose pigs to dust and airborne endotoxins in an environmental chamber, at levels liable to be encountered in pig farm buildings. The following parameters were evaluated in a chamber containing two pigs of 10 kg body-weight: inhalable and respirable dust gravimetric concentrations were measured using area samplers and expressed as mg/m3. The respirable dust concentration was also measured using a "TM digital microP respirable dust-measuring instrument', which has been shown to give similar results to the gravimetric method. The endotoxin concentration was evaluated using the Limulus-assay and expressed as ng/m3 of air containing the inhalable or respirable dust or as ng/mg of inhalable and respirable dust. Feed flour dust was introduced into the chamber to obtain different concentrations of inhalable and respirable dust ranging from 3.62 to 76.66 mg/m3 and from 0.24 to 1.40 mg/m3, respectively. The endotoxin concentration was modulated by mixing the feed flour with Escherichia coli endotoxins before blowing it into the chamber. The endotoxin concentrations in the air containing inhalable or respirable dust ranged from 28.9 to 270.0 ng/m3 and from 2.22 to 36.38 ng/m3, respectively, depending on the amount of endotoxins added to the dust. Data were also obtained in a piggery. The experimental setup detailed in this paper could be used to study the significance of air contaminants in the development of pig respiratory diseases.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Inhalable wood dust: Risk assessment of Occupational exposure

Background and Purpose: Wood dust have been approved as a harmful and carcinogenic agent for humans. This study aimed to evaluate risk assessment of Workers' exposure to inhalable wood dust among 100 workers in 25 furniture manufacturing workshops in one of the northern cities in Iran. Materials and Methods: NIOSH0501 method was used to assess the occupational exposure to Inhalable wood dust a...

متن کامل

Exposure of cotton workers in an experimental cardroom with reference to airborne endotoxins.

Workers from cotton mills were exposed to cotton dust during carding in an experimental cardroom. Cotton from different geographical locations with varying amounts of endotoxin were used. Exposure levels ranged from 0.6 to 3.6 mg dust/m3 (from a vertical elutriator) and from 0.1 to 8.0 micrograms/m3 of endotoxin. No relationship was found between the decrease in FEV1 over the workshift and the ...

متن کامل

Occupational and biological monitoring of workers exposed to airborne dust in Gol-e-Gohar Iron Ore mine: A Case-Control Study

Background and aims: Mining is categorized with considerable exposure to airborne contaminations. Regarding the high prevalence of diseases and the high population of workers in iron ore mines, the aim of this study was to investigate the effect of miners’ exposure to respirable dust compounds on the serum Malondialdehyde (MDA) levels. Methods: In this study, 92 non-smoker healthy workers of G...

متن کامل

Effects of dust phenomenon and impacts with emphasis on dust problems and present solutions in Khuzestan (Iran)

Background & Aims of the Study: According to statistics reported by the international organization, 500,000 people annually due to airborne particulate matter exposure of the air are dying prematurely. Studies show the dust storm is responsible for the 7.1 % increase of fatality. Control of particulate matter is one of the most important methods of direct and indirect effects of par...

متن کامل

Longitudinal study of dust and airborne endotoxin in the home.

To characterize the seasonal variability of endotoxin levels, we measured endotoxin in dust from the bed, bedroom floor, and kitchen floor in 20 homes, and in air from the bedroom in 15 of the homes. All homes were located in the greater Boston, Massachusetts, area and were sampled each month from April 1995 to June 1996. Outdoor air was collected at two locations. We found greater within-home ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Veterinary research

دوره 27 6  شماره 

صفحات  -

تاریخ انتشار 1996