Time-Resolved FRET -Based Approach for Antibody Detection – A New Serodiagnostic Concept
نویسندگان
چکیده
Förster resonance energy transfer (FRET) is a phenomenon widely utilized in biomedical research of macromolecular interactions. In FRET energy is transferred between two fluorophores, the donor and the acceptor. Herein we describe a novel approach utilizing time-resolved FRET (TR-FRET) for the detection of antibodies not only in a solution-phase homogenous assay but also in single- and two-step solid-phase assays. Our method is based on the principle that the Y-shaped immunoglobulin G molecule is able to simultaneously bind two identical antigen molecules. Hence, if a specific IgG is mixed with donor- and acceptor-labeled antigens, the binding of antigens can be measured by TR-FRET. Using donor- and acceptor-labeled streptavidins (SAs) in conjunction with a polyclonal and a monoclonal anti-SA antibody we demonstrate that this approach is fully functional. In addition we characterize the immune complexes responsible for the TR-FRET signal using density gradient ultracentrifugation and solid-phase immunoassays. The homogenous TR-FRET assay described provides a rapid and robust tool for antibody detection, with a wide potential in medical diagnostics.
منابع مشابه
Highly Sensitive FRET-Based Fluorescence Immunoassay for Detecting of Aflatoxin B1 Using Magnetic/Silica Core-Shell as a Signal Intensifier
Background: Recently, some new nanobiosensors using different nanoparticles or microarray systems for detection of mycotoxins have been designed . However, rapid, sensitive and early detection of aflatoxicosis would be very helpful to distinguish high-risk persons. Objectives: We report a highly sensitive competitive immunoassay using magnetic/silica core shell as a signal intensifier for the d...
متن کاملA Protein L -Based Immunodiagnostic Approach Utilizing Time-Resolved Förster Resonance Energy Transfer
Chelated lanthanides such as europium (Eu) have uniquely long fluorescence emission half-lives permitting their use in time-resolved fluorescence (TRF) assays. In Förster resonance energy transfer (FRET) a donor fluorophore transfers its emission energy to an acceptor fluorophore if in sufficiently close proximity. The use of time-resolved (TR) FRET minimizes the autofluorescence of molecules p...
متن کاملExpanding TranscreenerTM Assay Technology: ADP Detection using TR-FRET
Introduction The TranscreenerTM KINASE TR-FRET Assay is a competitive HTS assay that measures ADP, the invariant product of all kinase reactions. Previously we developed a monoclonal antibody and a fluorescent tracer that allow detection of ADP with >100-fold selectivity over ATP using a fluorescence polarization (FP) readout. To offer detection options to the HTS community, we formatted the Tr...
متن کاملCompetitive Homogeneous Immunoassay for Rapid Serodiagnosis of Hantavirus Disease.
In this study, we describe a competitive homogeneous immunoassay that makes use of Förster resonance energy transfer (FRET) in rapid detection of pathogen-specific antibodies. The assay principle is based on competition between a monoclonal antibody (MAb) and serum antibodies to a given antigen. In the assay, named competitive FRET immunoassay (CFRET-IA), the FRET signal is induced if MAb carry...
متن کاملCell surface detection of membrane protein interaction with homogeneous time-resolved fluorescence resonance energy transfer technology.
Direct or indirect interactions between membrane proteins at the cell surface play a central role in numerous cell processes, including possible synergistic effects between different types of receptors. Here we describe a method and tools to analyze membrane protein-protein interaction at the surface of living cells. This technology is based on the use of specific antibodies directed against ea...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 8 شماره
صفحات -
تاریخ انتشار 2013