Measurement of In-vivo Local Shear Modulus by Combining Multiple Phase Offsets MR Elastography

نویسندگان

  • Mikio Suga
  • Tetsuya Matsuda
  • Kotaro Minato
  • Osamu Oshiro
  • Kunihiro Chihara
  • Jun Okamoto
  • Osamu Takizawa
  • Masaru Komori
  • Takashi Takahashi
چکیده

To provide realistic surgical simulation, haptic feedback is important. In the existing surgical simulators, the fidelity of the deformation and haptic feedback is limited because they are based on the subjective evaluation of the expert-user and not on an objective model-based evaluation. To obtain elastic modulus of in-vivo human tissues, magnetic resonance elastography (MRE) was developed. MRE is a phase-contrast- based method that can visualize propagating strain waves in materials. The quantitative values of shear modulus can be calculated by estimating the local wavelength of the wave pattern. Low frequency mechanical motion must be used for soft tissue-like materials, because strain waves rapidly attenuate at higher frequency. Therefore, wavelength in MRE is long. It is difficult to estimate local wavelength with high spatial resolution especially from noisy MRE. In the MRE sequence, motion-sensitizing gradient (MSG) are synchronized with the mechanical cyclic motion. MRE with multiple initial phase offsets can be generated with increasing delays between the MSG and mechanical excitation. In this paper, we describe a method of measuring local wavelength with high spatial resolution by combining multiple phase offsets MRE. To confirm the reliability of this method, a computer simulation and phantom study were performed. The shear modulus measured with various elastic objects was well consistent with the value obtained by MRE and the mechanical method. The shear moduli of excised porcine liver and in-vivo human calf muscle were also analyzed by this method. on the subjective evaluation of an expert-user and not on objective model-based methods.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

MR Elastography Sequence Comparison: Standard PC MRE vs. Balanced Alternating Steady-State Elastography

S. Maderwald, F. Stock, O. Kraff, A. de Greiff, O. Bieri, K. Scheffler, M. E. Ladd Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen, Germany, MR Physics, Demartment of Medical Radiology, University of Basel, Basel, Switzerland Introduction MR elastography (MRE) has been shown to be capable of non-invasively measuring tissue elasticity ev...

متن کامل

The measurement of anisotropic elasticity in skeletal muscle using MR Elastography

T. Oida, Y. Kang, T. Azuma, J. Okamoto, A. Amano, L. Axel, O. Takizawa, S. Tsutsumi, T. Matsuda Graduate School of Informatics, Kyoto University, Kyoto, Kyoto, Japan, Institute for Frontier Medical Sciences, Kyoto University, Kyoto, Kyoto, Japan, Siem ens-Asahi Medical Technologies Ltd., Shinagawa-ku, Tokyo, Japan, Department of Radiology, New York University School of Medicine, New York, New Y...

متن کامل

Intensity speckle MR elastography

Introduction: Magnetic resonance elastography (MRE) allows the measurement of the mechanical properties of living tissue by combining shear waves and motion sensitive MRI [1]. In classical MRE, shear wave images are evaluated using an appropriate wave inversion technique for calculating an estimate of the spatial distribution of the shear modulus within the region of interest [2]. Problem: Wave...

متن کامل

In vivo MR elastography of liver: Comparison to oscillatory rheometer studies of tissue specimen

Introduction: Magnetic Resonance Elastography (MRE) is capable to measure the mechanical properties of living tissue by externally introduced shear vibrations and phase contrast MRI [1]. In multifrequency MRE the complex shear modulus G*(ω) of biological tissue is measured at various mechanical vibration frequencies simultaneously. Viscoelastic tissue parameters can then be calculated by fittin...

متن کامل

Quantitative shear wave magnetic resonance elastography: comparison to a dynamic shear material test.

Magnetic resonance elastography (MRE), a phase contrast MRI technique, images the propagation of applied mechanical waves in tissue, allowing shear stiffness to be quantified in vivo. This MRE technique has been validated with static mechanical compression tests. Dynamic mechanical analysis (DMA) may be a more appropriate comparison to MRE because it directly measures the shear modulus dynamica...

متن کامل